40 µL 384-Well PCR Plate, ABI®-Type, One-Notch

The Puretest 40 µL 384-well one-notch PCR plate provides high-density low-volume amplification in an ABI®-type full-skirted frame. Its 4.5 mm well pitch and rigid deck support high-throughput PCR, qPCR and automated reaction setup after instrument validation.

  • 384-well high-density array: Quadruples throughput relative to a 96-well plate in the same general footprint.
  • 40 µL nominal wells: Support low-volume reactions and reduced reagent consumption.
  • ABI®-type one-notch orientation: Helps identify the required instrument and loading direction.
  • Rigid full skirt: Supports robotic handling, stacking and barcode placement.
  • High-purity polypropylene wells: Support rapid thermal transfer and low nonspecific binding.

Request a sample, drawing or quotation

PRODUCT DETAILS

40 µL 384-Well PCR Plate, ABI®-Type, One-Notch for Consistent PCR and qPCR Workflows

The Puretest 40 µL 384-well one-notch PCR plate provides high-density low-volume amplification in an ABI®-type full-skirted frame. Its 4.5 mm well pitch and rigid deck support high-throughput PCR, qPCR and automated reaction setup after instrument validation.

Three hundred eighty-four thin-wall wells are arranged at 4.5 mm pitch within a full-skirt frame. The one-notch corner/orientation pattern is designed around selected ABI-type 384-well carriers. High-density geometry demands accurate pipetting and a flat, rigid deck.

Puretest 96-well and 384-well PCR plate family
Representative Puretest PCR plate structures, including full-skirted, semi-skirted, non-skirted and 384-well formats.

Product Highlights

  • 384-well high-density array: Quadruples throughput relative to a 96-well plate in the same general footprint.
  • 40 µL nominal wells: Support low-volume reactions and reduced reagent consumption.
  • ABI®-type one-notch orientation: Helps identify the required instrument and loading direction.
  • Rigid full skirt: Supports robotic handling, stacking and barcode placement.
  • High-purity polypropylene wells: Support rapid thermal transfer and low nonspecific binding.
  • Uniform thin-wall molding: Promotes consistent heating and cooling from well to well.
  • Raised sealing rims: Help films or heat seals close each reaction independently.
  • Alphanumeric indexing: Supports plate maps, sample identification and orientation.
  • Clear and white options: Select optical configuration according to the PCR or qPCR detection method.
  • Automation-oriented supply: Technical drawings, samples, barcode and private-label options are available.

Plate Structure and Functional Design

Three hundred eighty-four thin-wall wells are arranged at 4.5 mm pitch within a full-skirt frame. The one-notch corner/orientation pattern is designed around selected ABI-type 384-well carriers. High-density geometry demands accurate pipetting and a flat, rigid deck.

Use calibrated 384-channel or low-volume dispensing equipment where possible. Apply uniform sealing pressure and centrifuge in a fully supported 384-well carrier.

Technical Specifications

Plate format 384 wells; 16 × 24 array
Nominal well capacity 40 µL
Typical reaction-volume reference Approximately 5–20 µL; follow assay and instrument guidance
Skirt style Full skirt
Orientation ABI®-type one-notch frame
Material High-purity polypropylene (PP)
Pitch 4.5 mm nominal
Footprint ANSI/SLAS-style outer footprint
Color options Clear and white subject to quotation
Sealing 384-well optical adhesive film or compatible heat seal
Cleanliness Applicable DNase/RNase, pyrogen and PCR-inhibitor status confirmed for quoted SKU

Dimensions, working volumes and compatibility are nominal unless stated in the current Puretest drawing. Validate the exact instrument, seal and thermal protocol before routine use.

Instrument Compatibility and Selection Guide

Designed around selected ABI®-type 384-well blocks using a one-notch orientation. Confirm the exact instrument, notch position, corner cut, plate color and optical seal. A one-notch plate should not be substituted for a two-notch Roche®-type frame without validation.

  • Confirm the number of wells, block height, skirt style, corner cut and notch position.
  • For qPCR, confirm whether clear or white wells and an optical seal are required.
  • For automation, validate gripper access, deck carrier, barcode area and plate rigidity.
  • Request a physical sample before releasing a new plate into a validated assay.

Application Guide

Application Why This Format Is Suitable
High-throughput PCR Processes 384 reactions in a compact footprint.
qPCR / real-time PCR Low-volume optical wells support compatible detection systems.
SNP genotyping High density reduces plate count and reagent use.
Screening assays 384 positions support large sample or target panels.
Automated reaction setup Rigid skirt supports high-density dispensing and plate handling.

Sealing, Thermal Cycling and Handling

  • Use an optical adhesive film, heat seal or cap solution compatible with the plate and detection method.
  • Apply uniform sealing pressure and confirm that every well rim is fully closed before cycling.
  • Centrifuge briefly when the protocol requires liquid collection at the well bottom, using a supported carrier.
  • Keep wells and sealing rims free from powder, oil and fingerprints.
  • Nominal well capacity is not the recommended reaction volume; preserve headspace and follow the assay protocol.

Material, Cleanliness and Quality Documentation

Puretest laboratory consumables are molded from high-purity polypropylene selected for chemical resistance, low biomolecule binding and dependable dimensional consistency. Available cleanliness, sterile and packaging configurations must be matched to the quoted catalog number.

If your workflow requires a Certificate of Analysis, Certificate of Conformance, irradiation record, DNase/RNase status, pyrogen limit, human-DNA limit, dimensional report or batch traceability, state the requirement before ordering. Puretest will confirm which documents apply to the selected configuration rather than treating every supply option as identical.

Ordering Information, Packaging and OEM Support

Puretest supports evaluation samples, current technical drawings, bulk and individually protected packaging, sterile and non-sterile options, customer catalog numbers, private labels, barcodes and distributor carton programs. MOQ, inner-pack quantity, case quantity, lead time, carton dimensions and shipping method are confirmed with the final specification.

Choose the Right PCR Plate Format

Plate Format Well Count Frame / Orientation Best-Fit Workflow
40 µL 384-well one-notch 384 wells ABI®-type one-notch frame High-throughput low-volume PCR/qPCR
40 µL 384-well two-notch 384 wells Roche®-type two-notch frame Selected Roche®-type 384-well systems
0.1 mL full-skirted 96 wells Bio-Rad®-type frame Rigid low-profile PCR/qPCR workflows
0.1 mL semi-skirted FAST®-type 96 wells Low-profile semi skirt Fast-cycling block formats
0.1 mL semi-skirted LightCycler®-type 96 wells Notched semi skirt Selected LightCycler®-type instruments
0.2 mL non-skirted 96 wells Flexible non-skirted frame Broad routine PCR compatibility
0.2 mL semi-skirted ABI®-type 96 wells Raised semi skirt Selected ABI®-type blocks and automation
0.2 mL semi-skirted straight side 96 wells Straight-sided semi skirt Routine PCR and plate handling

Instrument names describe compatibility style only. Confirm the block format, skirt, corner cut, notch position, optical requirement and current drawing before ordering.

Trademark and Compatibility Notice

ABI®, Bio-Rad®, FAST®, LightCycler® and Roche® are trademarks of their respective owners. Puretest is not affiliated with or endorsed by those companies. Compatibility-style descriptions help buyers identify frame geometry and do not replace instrument validation.

Frequently Asked Questions

Why choose a 384-well plate?

It increases throughput and reduces reaction volume, but requires more precise dispensing and instrument matching.

What does one-notch mean?

It describes an orientation feature in the skirt. The notch must match the carrier and instrument geometry.

Can it replace a Roche®-type two-notch plate?

Not automatically. The skirt and orientation features differ.

What reaction volume is typical?

Many 384-well assays use approximately 5–20 µL, but follow the validated assay and instrument limits.

Which seal is required?

Use a 384-well optical film or compatible heat seal that maintains closure across the full high-density array.

Request a Sample, Drawing or Quotation

Tell us the required 40 µL 384-well one-notch, thermal cycler model, reaction volume, optical color, skirt and corner/notch requirement, annual quantity and destination country. Contact Puretest for a sample, current technical drawing, cleanliness-document confirmation or commercial quotation.

RELATED PRODUCTS

White breathable heat sealing film roll with a brown core and an unrolled membrane section
Breathable Heat Sealing Film
Transparent heat sealing film roll with a white core and clear unrolled film
Clear Heat Sealing Film
Roll of aluminum heat sealing foil with an unrolled silver foil section
Aluminum Heat Sealing Foil
Single pipette tip accessing a microplate well through a cross-shaped pre-slit sealing film opening
Pierceable and Pre-Slit Microplate Sealing Film
GET IN TOUCH

Contact Us

General Inquiries​

Leave info for details

Please leave your message here! We willsend detailed technical info and quotationto you!