40 µL 384-Well PCR Plate, Roche®-Type, Two-Notch

The Puretest 40 µL 384-well two-notch PCR plate combines high-density low-volume wells with a Roche®-type full-skirt frame. Two orientation notches distinguish the carrier geometry for compatible real-time PCR systems and automated workflows.

  • 384-well 16 × 24 array: Supports high-throughput amplification and screening.
  • 40 µL nominal wells: Reduce reagent use in validated low-volume assays.
  • Roche®-type two-notch frame: Provides distinct orientation for compatible 384-well instruments.
  • Rigid full skirt: Improves deck flatness, robotic handling and barcode access.
  • High-purity polypropylene wells: Support rapid thermal transfer and low nonspecific binding.

Request a sample, drawing or quotation

PRODUCT DETAILS

40 µL 384-Well PCR Plate, Roche®-Type, Two-Notch for Consistent PCR and qPCR Workflows

The Puretest 40 µL 384-well two-notch PCR plate combines high-density low-volume wells with a Roche®-type full-skirt frame. Two orientation notches distinguish the carrier geometry for compatible real-time PCR systems and automated workflows.

The full-skirt frame holds 384 thin-wall wells at 4.5 mm pitch and includes two instrument-oriented notches. These features help align the plate in selected Roche-type carriers, while the rigid perimeter supports uniform sealing and automated handling.

Puretest 96-well and 384-well PCR plate family
Representative Puretest PCR plate structures, including full-skirted, semi-skirted, non-skirted and 384-well formats.

Product Highlights

  • 384-well 16 × 24 array: Supports high-throughput amplification and screening.
  • 40 µL nominal wells: Reduce reagent use in validated low-volume assays.
  • Roche®-type two-notch frame: Provides distinct orientation for compatible 384-well instruments.
  • Rigid full skirt: Improves deck flatness, robotic handling and barcode access.
  • High-purity polypropylene wells: Support rapid thermal transfer and low nonspecific binding.
  • Uniform thin-wall molding: Promotes consistent heating and cooling from well to well.
  • Raised sealing rims: Help films or heat seals close each reaction independently.
  • Alphanumeric indexing: Supports plate maps, sample identification and orientation.
  • Clear and white options: Select optical configuration according to the PCR or qPCR detection method.
  • Automation-oriented supply: Technical drawings, samples, barcode and private-label options are available.

Plate Structure and Functional Design

The full-skirt frame holds 384 thin-wall wells at 4.5 mm pitch and includes two instrument-oriented notches. These features help align the plate in selected Roche-type carriers, while the rigid perimeter supports uniform sealing and automated handling.

Check both orientation notches before loading the instrument. Use low-volume calibrated pipetting and a full-support carrier during centrifugation and sealing.

Technical Specifications

Plate format 384 wells; 16 × 24 array
Nominal well capacity 40 µL
Typical reaction-volume reference Approximately 5–20 µL; follow assay and instrument guidance
Skirt style Full skirt
Orientation Roche®-type two-notch frame
Material High-purity polypropylene (PP)
Pitch 4.5 mm nominal
Footprint ANSI/SLAS-style outer footprint
Color options Clear and white subject to quotation
Sealing 384-well optical adhesive film or compatible heat seal
Cleanliness Applicable DNase/RNase, pyrogen and PCR-inhibitor status confirmed for quoted SKU

Dimensions, working volumes and compatibility are nominal unless stated in the current Puretest drawing. Validate the exact instrument, seal and thermal protocol before routine use.

Instrument Compatibility and Selection Guide

Designed around selected Roche®-type 384-well carriers using a two-notch orientation. Confirm the exact LightCycler or other instrument model, notch position, well color and optical seal. Do not assume compatibility from well count alone.

  • Confirm the number of wells, block height, skirt style, corner cut and notch position.
  • For qPCR, confirm whether clear or white wells and an optical seal are required.
  • For automation, validate gripper access, deck carrier, barcode area and plate rigidity.
  • Request a physical sample before releasing a new plate into a validated assay.

Application Guide

Application Why This Format Is Suitable
High-throughput qPCR 384 low-volume wells support compatible real-time detection platforms.
Gene-expression profiling High density supports large target and sample matrices.
Genotyping Low-volume format reduces reagent consumption.
Screening workflows Rigid plate geometry supports automated reaction setup.
Molecular assay development Provides a two-notch frame for compatible instrument validation.

Sealing, Thermal Cycling and Handling

  • Use an optical adhesive film, heat seal or cap solution compatible with the plate and detection method.
  • Apply uniform sealing pressure and confirm that every well rim is fully closed before cycling.
  • Centrifuge briefly when the protocol requires liquid collection at the well bottom, using a supported carrier.
  • Keep wells and sealing rims free from powder, oil and fingerprints.
  • Nominal well capacity is not the recommended reaction volume; preserve headspace and follow the assay protocol.

Material, Cleanliness and Quality Documentation

Puretest laboratory consumables are molded from high-purity polypropylene selected for chemical resistance, low biomolecule binding and dependable dimensional consistency. Available cleanliness, sterile and packaging configurations must be matched to the quoted catalog number.

If your workflow requires a Certificate of Analysis, Certificate of Conformance, irradiation record, DNase/RNase status, pyrogen limit, human-DNA limit, dimensional report or batch traceability, state the requirement before ordering. Puretest will confirm which documents apply to the selected configuration rather than treating every supply option as identical.

Ordering Information, Packaging and OEM Support

Puretest supports evaluation samples, current technical drawings, bulk and individually protected packaging, sterile and non-sterile options, customer catalog numbers, private labels, barcodes and distributor carton programs. MOQ, inner-pack quantity, case quantity, lead time, carton dimensions and shipping method are confirmed with the final specification.

Choose the Right PCR Plate Format

Plate Format Well Count Frame / Orientation Best-Fit Workflow
40 µL 384-well one-notch 384 wells ABI®-type one-notch frame High-throughput low-volume PCR/qPCR
40 µL 384-well two-notch 384 wells Roche®-type two-notch frame Selected Roche®-type 384-well systems
0.1 mL full-skirted 96 wells Bio-Rad®-type frame Rigid low-profile PCR/qPCR workflows
0.1 mL semi-skirted FAST®-type 96 wells Low-profile semi skirt Fast-cycling block formats
0.1 mL semi-skirted LightCycler®-type 96 wells Notched semi skirt Selected LightCycler®-type instruments
0.2 mL non-skirted 96 wells Flexible non-skirted frame Broad routine PCR compatibility
0.2 mL semi-skirted ABI®-type 96 wells Raised semi skirt Selected ABI®-type blocks and automation
0.2 mL semi-skirted straight side 96 wells Straight-sided semi skirt Routine PCR and plate handling

Instrument names describe compatibility style only. Confirm the block format, skirt, corner cut, notch position, optical requirement and current drawing before ordering.

Trademark and Compatibility Notice

ABI®, Bio-Rad®, FAST®, LightCycler® and Roche® are trademarks of their respective owners. Puretest is not affiliated with or endorsed by those companies. Compatibility-style descriptions help buyers identify frame geometry and do not replace instrument validation.

Frequently Asked Questions

How is this different from the ABI®-type one-notch plate?

The skirt orientation features differ. Use the plate designed for the exact carrier and instrument.

Is the plate only for qPCR?

It can support PCR, qPCR and other compatible thermal workflows, but optical color and sealing requirements vary.

Why are white wells often used?

White wells can improve fluorescence reflection and reduce optical cross-talk in some qPCR systems.

Can it be handled robotically?

Yes after validating the gripper, deck carrier, plate height and barcode location.

Can Puretest provide both notch styles?

Yes. State the instrument model so the correct one-notch or two-notch sample can be supplied.

Request a Sample, Drawing or Quotation

Tell us the required 40 µL 384-well two-notch, thermal cycler model, reaction volume, optical color, skirt and corner/notch requirement, annual quantity and destination country. Contact Puretest for a sample, current technical drawing, cleanliness-document confirmation or commercial quotation.

RELATED PRODUCTS

40 µL 384-well PCR plate with ABI-type one-notch frame
40 µL 384-Well PCR Plate, ABI®-Type, One-Notch
0.1 mL 96-well full-skirted PCR plate with Bio-Rad-type frame
0.1 mL 96-Well Full-Skirted PCR Plate, Bio-Rad®-Type
0.1 mL 96-well semi-skirted PCR plate with FAST-type frame
0.1 mL 96-Well Semi-Skirted PCR Plate, FAST®-Type
0.1 mL 96-well semi-skirted PCR plate with LightCycler-type frame
0.1 mL 96-Well Semi-Skirted PCR Plate, LightCycler®-Type
GET IN TOUCH

Contact Us

General Inquiries​

Tell us the product, specifications and estimated quantity. We will reply by email with the next steps.

Request a Quote or Sample

Tell us the product, specifications and quantity you need. We’ll reply by email with the next steps.