Cell culture dish range guide. This original URL is retained for existing links. The range is now presented on seven individual product pages for 35, 60 and 100 mm standard / gripping-ring dishes, and the 150 mm standard dish.
View the current size-specific cell culture dishes, or select a configuration in the guide below.
This retained range guide links to the current individual product pages. For the latest configuration-specific photographs, technical details and ordering information, select a dish below.
Puretest cell culture dishes provide a clear polystyrene (PS) culture vessel with a flat, tissue-culture-treated growth surface and a matching lid. The series covers four nominal sizes: 35 mm, 60 mm, 100 mm and 150 mm. Choose by culture area, medium requirement and handling preference rather than diameter alone.
Standard and gripping-ring configurations are listed separately below. The gripping ring helps with gloved handling and dish separation; it is a model-specific feature, not a feature assumed for every size. Product photographs illustrate the dish and lid structure and are not a dimensional scale drawing.
The following reference configurations support specification matching. Nominal diameter is the format designation, not a measured inner diameter. Growth area is the usable culture surface; recommended medium volume is a working range, not the maximum vessel capacity.
| Nominal size | Configuration | Height (mm) | Growth area (cm2) | Medium (mL) | Pieces/pack | Pieces/case |
|---|---|---|---|---|---|---|
| 35 mm | Standard | 12 | 8.5 | 1.8–2.7 | 20 | 500 |
| 35 mm | With gripping ring | 12 | 8.5 | 1.8–2.7 | 20 | 500 |
| 60 mm | Standard | 15 | 22.9 | 4.2–6.3 | 20 | 500 |
| 60 mm | With gripping ring | 15 | 22.9 | 4.2–6.3 | 20 | 500 |
| 100 mm | Standard | 20 | 57.6 | 11–16.5 | 5, 10 or 20* | 300 |
| 100 mm | With gripping ring | 20 | 59.3 | 11–16.5 | 10 or 20* | 300 |
| 150 mm | Standard | 25 | 150.1 | 30.4–45.6 | 5 | 100 |
*Different pack counts represent separate packing configurations, not mixed packs. These are reference values for enquiry and comparison; confirm the matched Puretest item, technical drawing, tolerances, pack count and availability in the quotation before ordering. No 150 mm gripping-ring configuration is specified here.
Final medium volume, seeding density and incubation conditions must follow the cell line and validated laboratory protocol. Nominal size alone does not establish equipment compatibility; request the drawing if holder fit or optical clearance is critical.
Suitable selection areas include adherent-cell maintenance, expansion, colony assays and preparation for downstream harvesting. Evaluate the selected dish with your cell type and imaging setup before routine use. These PS dishes are not glass-bottom dishes or untreated microbiological Petri dishes.
Open the sterile pack in an appropriate clean working environment, avoid touching the culture surface and use aseptic technique. Store unopened packs according to the product label and use before the stated expiry date. Do not reuse or autoclave unless the supplied product instructions explicitly permit it.
For a matched quotation, specify nominal size, standard or gripping-ring design, preferred pack quantity, total quantity and destination. Request the applicable material specification, sterilization method and batch documentation for the selected item. Sterility assurance levels, DNase/RNase status, pyrogen limits and certification claims must be supported by the supplied product documentation; they are not inferred from another manufacturer’s product listing.
Samples, private-label packaging, MOQ and lead time can be discussed for the required configuration. Contact Puretest for a size-matched sample or quotation.
No. This page lists four discrete nominal sizes: 35, 60, 100 and 150 mm. It does not claim any intermediate diameter.
No. The guide lists gripping-ring configurations for 35, 60 and 100 mm only. Confirm the exact configuration when ordering.
Not necessarily. TC treatment supports many adherent-cell workflows, but some cells require a specific coating or substrate. Follow the cell supplier’s protocol.
No. They are recommended working-volume ranges. The optimum volume depends on the cells and the culture protocol.
No. The main image shows the complete dish and lid; the second image is a rim detail. Use the confirmed technical drawing for dimensions and tolerances.
General Inquiries
Enquiry for: TC-Treated Cell Culture Dishes, Sterile
Tell us what you need. You can ask for a quote, samples or help choosing a specification.
We use necessary cookies to run this website. With your permission, we also use analytics, Google Ads conversion measurement, and optional services such as live chat and embedded maps. You can reject optional cookies and still browse products or send an enquiry. Change your choices anytime in Cookie settings.
Tell us the product, specifications and quantity you need. We’ll reply by email with the next steps.