PRODUCTS

60 mm TC-Treated Cell Culture Dish, Sterile

60 mm sterile, TC-treated polystyrene cell culture dish for routine culture and colony studies, supplied with a matching lid.

  • Standard — without gripping ring
  • 22.9 cm² reference growth area; 15 mm height
  • 4.2–6.3 mL recommended medium

PRODUCT DETAILS

Product Highlights

An intermediate format for routine culture work. The 60 mm standard dish offers a 22.9 cm² reference growth area and a recommended reference medium range of 4.2–6.3 mL. It provides an intermediate option between the 35 mm and 100 mm formats for routine adherent-cell culture, observation and cell harvesting. This model is supplied without an external gripping ring.

  • Specified culture format: 60 mm nominal format, 15 mm height and 22.9 cm² reference growth area.
  • TC-treated polystyrene: A transparent culture surface for adherent-cell workflows.
  • Defined handling configuration: standard, without gripping ring; supplied with a matching lid.
  • Medium planning: 4.2–6.3 mL reference working range per dish, not maximum vessel capacity.

Structure & Functional Design

The flat culture base gives access for medium exchange and cell harvesting. Transparent PS allows routine inspection; for demanding microscopy, specify the required optical surface rather than assuming a standard PS dish is equivalent to glass-bottom ware.

The standard rim provides a simple dish-and-lid configuration without an external gripping ring. If a gripping ring is specified in your protocol or purchasing description, use the separate ring-version listing. The lift-off lid allows access across the dish. Keep the vessel upright; it is not a sealed specimen-transport container.

Applications

  • Routine adherent-cell maintenance in an intermediate dish format.
  • Culture-condition comparisons requiring more area than a 35 mm dish.
  • Preparation of cells for subsequent harvesting or assays.

Cell attachment and growth remain cell-line and protocol dependent. Where a specialist coating is required, follow the cell supplier’s instructions and qualify the selected surface.

Technical Specifications

Dimensions, growth area, medium range and packing below are reference configurations for quotation matching. The final Puretest item drawing and supplied specification govern an order; nominal format is not a measured internal diameter.

Parameter Specification
Nominal format 60 mm
Configuration standard, without gripping ring
Height 15 mm
Growth area 22.9 cm²
Recommended medium 4.2–6.3 mL
Material Transparent polystyrene (PS)
Culture surface TC-treated
Lid Matching lift-off lid
Supply format Sterile; single use
Intended use Laboratory research

Ordering Information

Configuration Dishes / pack Dishes / case
60 mm; standard 20 500

For a quotation, identify 60 mm, standard, without gripping ring, the required pack size, total quantity and destination. Pack options above are reference arrangements, not a statement of current stock.

MOQ, lead time, sample availability and any private-label packaging requirements are confirmed in the quotation. For supplier qualification, specify the batch documentation and test evidence your purchasing process requires.

Sterility, Handling & Storage

Open intact sterile packaging using aseptic technique and avoid touching the culture surface. Store unopened packs according to the supplied label and use within its expiry date. These are single-use culture dishes, not reusable glassware.

Qualification documents: Sterilization method, shelf life and any DNase/RNase or endotoxin testing must be supported by documentation for the supplied item. This page does not assert those unverified quality claims.

Frequently Asked Questions

How does this configuration differ from the other formats?

The 60 mm standard and gripping-ring versions share the listed 22.9 cm² reference growth area, but their handling rims are different. Select the configuration explicitly in your enquiry.

How much medium should I plan per dish?

The reference working range is 4.2–6.3 mL. Adjust medium depth, exchange frequency and cell input using your validated culture protocol; the range is not a fill-capacity rating.

Which pack size should I specify?

This configuration has 20 dishes per reference pack and 500 dishes per reference case. Include the preferred pack in the enquiry so case quantities and the final supply arrangement can be confirmed together.

Can the dish be selected by diameter alone?

No. Check the configuration, growth area and medium range together. For use in holders, automated systems or imaging equipment, compare the exact outside dimensions and clearance against the confirmed item drawing.

Request a Quotation

Send your requirements for the 60 mm standard, without gripping ring cell culture dish to sales@biopuretest.com, or use the product enquiry form.

Compare the 60 mm TC-Treated Cell Culture Dish with Gripping Ring, Sterile or browse the complete Cell Culture Dishes range.

RELATED PRODUCTS

Tall ten-position Type A Westergren ESR rack with a graduated detection tube
Westergren ESR Rack and Tube System — Type A
Ten-position ESR test rack with original graduated scales and bubble level
10-Position ESR Test Rack
Low-profile ten-position Type B Westergren ESR rack with matched tubes and reservoirs
Westergren ESR Rack and Tube System — Type B
Black-cap sodium citrate ESR blood collection tubes in slender and standard formats
Sodium Citrate ESR Blood Collection Tube
GET IN TOUCH

Contact Us

General Inquiries​

Request a Quote or Sample