PRODUCTS

100 mm TC-Treated Cell Culture Dish with Gripping Ring, Sterile

100 mm sterile, TC-treated polystyrene cell culture dish for adherent-cell expansion and harvest preparation, supplied with a matching lid.

  • With gripping ring
  • 59.3 cm² reference growth area; 20 mm height
  • 11–16.5 mL recommended medium

PRODUCT DETAILS

Product Highlights

A 100 mm gripping-ring dish with its own growth-area specification. The 100 mm gripping-ring dish has a 59.3 cm² reference growth area. This is not the same area as the 57.6 cm² standard-rim version, even though both use the nominal 100 mm designation. Select by configuration and growth area together, especially when transferring a seeding-density calculation between vessels.

  • Specified culture format: 100 mm nominal format, 20 mm height and 59.3 cm² reference growth area.
  • TC-treated polystyrene: A transparent culture surface for adherent-cell workflows.
  • Defined handling configuration: with gripping ring; supplied with a matching lid.
  • Medium planning: 11–16.5 mL reference working range per dish, not maximum vessel capacity.

Structure & Functional Design

The flat culture base gives access for medium exchange and cell harvesting. Transparent PS allows routine inspection; for demanding microscopy, specify the required optical surface rather than assuming a standard PS dish is equivalent to glass-bottom ware.

An external gripping ring distinguishes this version from the standard rim. It is a handling feature, not an additional culture surface or a leakproof closure. The lift-off lid allows access across the dish. Keep the vessel upright; it is not a sealed specimen-transport container.

Applications

  • Larger adherent-cell cultures with an external gripping-ring requirement.
  • Culture transfer between formats using growth area to plan cell input.
  • Routine cell expansion with 10- or 20-dish reference pack options.

Cell attachment and growth remain cell-line and protocol dependent. Where a specialist coating is required, follow the cell supplier’s instructions and qualify the selected surface.

Technical Specifications

Dimensions, growth area, medium range and packing below are reference configurations for quotation matching. The final Puretest item drawing and supplied specification govern an order; nominal format is not a measured internal diameter.

Parameter Specification
Nominal format 100 mm
Configuration with gripping ring
Height 20 mm
Growth area 59.3 cm²
Recommended medium 11–16.5 mL
Material Transparent polystyrene (PS)
Culture surface TC-treated
Lid Matching lift-off lid
Supply format Sterile; single use
Intended use Laboratory research

Ordering Information

Configuration Dishes / pack Dishes / case
100 mm; gripping ring 10 300
100 mm; gripping ring 20 300

For a quotation, identify 100 mm, with gripping ring, the required pack size, total quantity and destination. Pack options above are reference arrangements, not a statement of current stock.

MOQ, lead time, sample availability and any private-label packaging requirements are confirmed in the quotation. For supplier qualification, specify the batch documentation and test evidence your purchasing process requires.

Sterility, Handling & Storage

Open intact sterile packaging using aseptic technique and avoid touching the culture surface. Store unopened packs according to the supplied label and use within its expiry date. These are single-use culture dishes, not reusable glassware.

Qualification documents: Sterilization method, shelf life and any DNase/RNase or endotoxin testing must be supported by documentation for the supplied item. This page does not assert those unverified quality claims.

Frequently Asked Questions

How does this configuration differ from the other formats?

Use 59.3 cm² for this configuration. The other 100 mm version has 57.6 cm² of reference growth area; nominal size alone does not establish an identical culture surface.

How much medium should I plan per dish?

The reference working range is 11–16.5 mL. Adjust medium depth, exchange frequency and cell input using your validated culture protocol; the range is not a fill-capacity rating.

Which pack size should I specify?

This configuration has 10 dishes, or 20 dishes per reference pack and 300 dishes per reference case. Include the preferred pack in the enquiry so case quantities and the final supply arrangement can be confirmed together.

Can the dish be selected by diameter alone?

No. Check the configuration, growth area and medium range together. For use in holders, automated systems or imaging equipment, compare the exact outside dimensions and clearance against the confirmed item drawing.

Request a Quotation

Send your requirements for the 100 mm with gripping ring cell culture dish to sales@biopuretest.com, or use the product enquiry form.

Compare the 100 mm TC-Treated Cell Culture Dish, Sterile or browse the complete Cell Culture Dishes range.

RELATED PRODUCTS

Tall ten-position Type A Westergren ESR rack with a graduated detection tube
Westergren ESR Rack and Tube System — Type A
Ten-position ESR test rack with original graduated scales and bubble level
10-Position ESR Test Rack
Low-profile ten-position Type B Westergren ESR rack with matched tubes and reservoirs
Westergren ESR Rack and Tube System — Type B
Black-cap sodium citrate ESR blood collection tubes in slender and standard formats
Sodium Citrate ESR Blood Collection Tube
GET IN TOUCH

Contact Us

General Inquiries​

Request a Quote or Sample

Tell us the product, specifications and quantity you need. We’ll reply by email with the next steps.