96-Well ELISA Strip Plate, Removable 8-Well Strips

Puretest removable ELISA strip plates combine clear flat-bottom polystyrene wells with a supporting frame. Twelve detachable 8-well strips form a complete 96-well layout, allowing the number of strips to be matched to each assay run.

  • Flexible batch size: use the strips needed for samples, standards and controls.
  • 12 × 8-well format: maintain an organized 96-position plate map.
  • Clear flat-bottom wells: for colorimetric ELISA development.
  • Surface selection: specify your protein-binding grade and instrument requirements.

Request samples, specifications or a quotation →

PRODUCT DETAILS

Removable 96-Well ELISA Strip Plates for Flexible Assay Runs

Not every ELISA run needs a full plate. Puretest removable ELISA plates use twelve 8-well strips in a support frame, providing 96 positions when fully assembled. This modular format allows laboratories to plan smaller batches without handling a new fixed-well plate for every run.

The clear polystyrene wells have flat bottoms for absorbance-based assay workflows. Choose the binding surface to match your coating chemistry, and evaluate the complete strip-and-frame assembly on the intended reader or washer. For full-batch work with permanently fixed wells, see our 96-well solid ELISA plate.

Product Highlights

  • Detachable 8-well modules: select the strip count around the total wells required for a run.
  • 96-position support frame: holds the strips in an organized layout during handling and instrument loading.
  • Clear flat-bottom wells: allow visual inspection and support colorimetric absorbance measurements after assay validation.
  • Polystyrene binding surface: suitable for evaluating passive coating protocols with a selected surface grade.
  • Row and column identification: helps track strip positions, standards and sample replicates.
  • Supply configuration: confirm the frame, strip quantity and protective packaging for the selected order.

Plate Structure and Functional Design

Structural feature Function and handling consideration
Removable eight-well strip Groups eight reaction wells into one module. This description refers to removable strips; it does not assume the wells can be individually snapped apart.
Support frame Maintains the location of installed strips. Ensure each strip is fully seated and level before pipetting or instrument loading.
Flat-bottom wells Provide an optical reading surface. Avoid scratches or fingerprints on the underside.
Clear polystyrene Makes liquid levels, bubbles and residual wash liquid visible during setup and inspection.
Position markings Help preserve orientation after loading or removing strips. Record the original location in your plate map.

The product images show removable strips beside the frame, with vacant frame positions visible. Background and lighting have been edited for presentation. The detail view shows the same strip-and-frame configuration, not a separate product variant. Confirm the supplied strip count, frame and accessories in the quotation.

Technical Specifications

Parameter Specification / selection information
Product format Removable-strip ELISA microplate
Fully assembled capacity 96 reaction wells
Strip arrangement 12 strips × 8 wells
Assembled layout 8 rows × 12 columns
Well material Polystyrene (PS)
Well appearance Clear
Well bottom Flat bottom
Support Rectangular strip-holding frame
Binding surface Specify high- or medium-binding requirements; for low-binding or other surface needs, ask for the matching configuration
Assay coating No target-specific antibody or antigen coating is specified; develop coating and blocking with your assay protocol
Packaging Specify the required protective packaging, assemblies per carton and any separate strip supply in the quotation
Volume / dimensional data Request the selected product drawing and recommended working-volume information
Quality requirements Confirm the required sterility, nuclease, endotoxin and lot-documentation status in the supply specification
Intended use Laboratory research and assay development; not supplied here as a validated diagnostic test

Plan the Strip Count Around Your Assay

Count all required wells, including standards, blanks, controls and replicates, then round up to a whole number of 8-well strips. The examples below describe well positions, not sample capacity; the number of samples depends on the assay layout.

Total wells required Strips to load Available positions
24 wells 3 strips 24 positions
40 wells 5 strips 40 positions
50 wells 7 strips 56 positions
96 wells 12 strips 96 positions

Use only a partial-frame arrangement permitted by the instrument and the validated method. Some washers or automated handlers require a complete frame or specific loading positions. Do not assume an empty frame slot can be ignored by the instrument.

Binding Surface and Readout Selection

Choose the surface around the molecule being immobilized, not only the product name. A high-binding surface may help with protein immobilization, while another grade may give a more useful balance of signal and nonspecific adsorption. Compare the blank, signal-to-background ratio and replicate variation under the same assay conditions.

The clear format shown here is intended for consideration in colorimetric ELISA workflows. Fluorescence or luminescence may require a different optical plate construction. Ask about configuration availability and validate with the planned detection chemistry rather than treating clear, white and black plates as interchangeable.

Applications

  • Partial-plate ELISA runs with varying daily sample numbers.
  • Research assay development using direct, indirect, sandwich or competitive formats with suitable reagents.
  • Side-by-side evaluation of coating buffers, blocking conditions or sample dilutions.
  • Consumable qualification by laboratory, distribution and assay-development teams.

Strip Handling and Instrument Setup

  1. Create the map: define strip positions and assign standards, controls and samples before loading.
  2. Seat the strips: handle the frame and strip edges; check that every module sits level and faces the same direction.
  3. Protect unused material: keep unused strips clean and protected according to the supplied storage instructions. Do not return used strips to unused stock.
  4. Check the wash program: confirm the active positions, aspiration height and liquid volumes for a partial-plate run.
  5. Inspect before reading: remove bubbles and underside droplets, verify orientation and select the appropriate reader layout.

Used wells are not intended to be cleaned and reused for a new assay. Treat the plate as a single-use assay consumable. Follow laboratory procedures for disposal of exposed material.

Ordering Information

Tell us your requirement Detail to include
Plate configuration 96-well removable plate with 12 × 8-well strips and support frame
Binding and readout Required surface grade, coating molecule where relevant, and detection chemistry
Supply format Complete assemblies or a request for separate strips; confirm frame inclusion and compatibility
Quantity and packaging Trial quantity, expected bulk demand, carton preference and labeling needs
Compatibility review Reader/washer model and any dimensional drawing for the currently used consumable
Delivery and documentation Destination country, required delivery window and quality documents for supplier qualification

These details help avoid quoting an incompatible frame or a surface grade that does not suit your method. Sample availability, pack quantities and lead time should be confirmed for the selected configuration before ordering.

Frequently Asked Questions

How many strips are in a complete plate?

A fully assembled 96-well plate contains twelve strips with eight wells each. The individual strip is the modular unit described on this page.

Can I use fewer than twelve strips?

Yes, the removable format enables partial-plate planning. First confirm that your reader, washer and handling method support the intended arrangement, and still include the controls required by the assay.

Are the individual wells breakable?

Removing an entire strip and separating individual wells are different features. Individual-well breakability is not specified for this listing. Confirm the required strip construction against the product drawing before ordering.

Can I mix strips from different plate types or lots?

Do not assume interchangeability. Strip fit, binding surface and manufacturing variation may affect handling or assay comparisons. Qualify the exact strip/frame combination and follow the lot-consistency requirements of your method.

Is the frame included, and can I buy strips separately?

The illustrated product is an assembled strip plate with a supporting frame. Include your requested supply format in the inquiry; ask the team to confirm frame inclusion and availability of separate strips.

Is this an ELISA kit or a PCR strip?

Neither. It is an ELISA plate consumable without a specified target-specific reagent system. It is not a thin-wall PCR tube strip for thermal cycling.

Find the Right Strip Plate Configuration

Send your required binding grade, trial or bulk quantity, reader/washer model and delivery country for a focused product and quotation review.

Request a Quote or Sample

Prefer fixed wells? Explore the 96-well solid ELISA plate.

RELATED PRODUCTS

Gray-cap blood collection tubes with sodium fluoride and sodium heparin for glucose testing
Fluoride Glucose Blood Collection Tube
Illustrative rendering of a Sysmex CA530-compatible coagulation cuvette with an elongated cylindrical body, rounded closed end and circular flange
Coagulation Cuvettes Compatible with Sysmex CA530
Green-cap heparin blood collection tubes with transparent bodies and no separator gel
Heparin Blood Collection Tube
Illustrative rendering of a TECO large single-channel coagulation cuvette with a flanged mouth and tapered lower chamber
Large Cuvettes for TECO Single-Channel Coagulation Analyzers