48-Well TC-Treated Cell Culture Plate, Flat Bottom, Sterile

Sterile 48-well TC-treated polystyrene plate for efficient screening, optimization and replicate-heavy cell studies. Lower working volume reduces media and compound use per condition.

  • Approx. 0.95 cm2 growth area per well
  • Typical working volume: 0.19-0.285 mL per well
  • Clear flat bottoms and matching lid
  • Gamma irradiated; individually sealed
  • Samples, technical documents and OEM support available

Request a sample or quotation

PRODUCT DETAILS

48-Well TC-Treated Cell Culture Plate for Efficient Screening and Optimization

The Puretest 48-well TC-treated cell culture plate increases experimental capacity while using less medium and reagent per condition than 6-, 12- or 24-well formats. Each well provides approximately 0.95 cm2 of growth area, making the plate a practical choice for screening, optimization and replicate-heavy studies that still require convenient manual access and useful cell yield.

The 6 x 8 plate combines a uniform tissue-culture-treated surface, clear flat well bottoms and a matching lid. It is suited to dose-response testing, media and coating optimization, cell viability studies, cytotoxicity assays, microscopy and image-based analysis. Each plate is gamma-irradiation sterilized and individually sealed for aseptic preparation.

Product Highlights

  • Efficient 48-well format: Provides twice the condition capacity of a 24-well plate while remaining accessible for manual workflows.
  • Uniform TC-treated surface: Improves hydrophilicity for attachment and spreading of many adherent cell types.
  • Clear flat bottoms: Support routine visual inspection, inverted microscopy, imaging and cell-based measurements.
  • Lower reagent use: The smaller growth area and working volume reduce media, coating and treatment consumption per condition.
  • Individually identified wells: Simplify concentration series, replicate mapping and sample tracking.
  • Raised well rims: Help reduce accidental liquid carryover between adjacent wells during careful pipetting.
  • Matching vented lid: Helps protect cultures while supporting gas exchange and routine incubator use.
  • Individual sterile pouch: Allows single-plate access without exposing unused inventory.

Plate Structure and Functional Design

The plate uses 48 individually separated wells arranged in a 6 x 8 layout. Each well has an approximate diameter of 11.0 mm, an approximate growth area of 0.95 cm2 and an approximate total volume of 1.6 mL. A typical culture-medium range is approximately 0.19-0.285 mL per well, supporting efficient surface coverage while conserving media and test compounds.

Compared with a 96-well plate, the 48-well format gives operators more room for manual pipetting, washing and imaging. It is often selected during assay development before a workflow is transferred to a higher-throughput 96-well format.

Technical Specifications

Plate format 48 wells
Well layout 6 x 8
Material High-clarity polystyrene (PS)
Surface treatment Tissue-culture treated (TC-treated)
Bottom Clear, flat bottom
Approx. growth area 0.95 cm2 per well
Typical working volume 0.19-0.285 mL per well
Approx. total well volume 1.6 mL per well
Approx. well diameter 11.0 mm
Approx. plate footprint 127.8 x 85.5 mm
Lid Included; designed for covered incubation and handling
Sterilization Gamma irradiation
Cleanliness profile Non-pyrogenic; DNase/RNase-free
Primary packaging 1 plate per individual sealed pouch
Use Single use; for laboratory research use only
Recommended storage 5-30°C; keep dry and away from direct sunlight
Shelf life 3 years from date of manufacture when stored as directed

Dimensions and volumes are nominal. Confirm the current technical drawing, tolerances, packaging quantity and applicable quality documentation with Puretest before placing a production order or validating automated equipment.

What Does TC-Treated Mean?

Untreated polystyrene is naturally hydrophobic and may not provide reliable attachment for many anchorage-dependent cells. Tissue-culture treatment improves surface hydrophilicity, helping many adherent cells attach, spread and form more consistent monolayers.

This plate is intended primarily for adherent-cell workflows. Suspension cells, low-attachment models and specialized assays may require a non-treated or application-specific surface.

Application Guide

Application Why the 48-Well Format Is Suitable
Dose-response screening Supports more concentration points and replicates while reducing compound and medium use.
Cell viability or cytotoxicity assays Balances throughput with enough well area for routine observation and endpoint analysis.
Media and coating optimization Enables efficient comparison of multiple formulations and surface conditions.
Transfection optimization Allows reagent-ratio and dose matrices with lower material consumption.
Microscopy and image analysis Clear flat bottoms support routine imaging with compatible instruments.
Replicate-heavy study design Provides enough wells for controls, technical replicates and several treatment groups.
Assay transfer and development Offers an intermediate step between manually accessible 24-well and higher-throughput 96-well formats.

Equipment and Workflow Compatibility

The approximately standard microplate footprint is suitable for many workflows, including standard CO2 incubators, compatible inverted microscopes and imaging systems, manual and multichannel pipetting, plate shakers that accept the plate dimensions and selected automated liquid-handling platforms.

For optical or automated use, confirm plate-carrier fit, focal requirements, deck compatibility and handling parameters using the current product drawing.

General Handling Recommendations

  1. Open the sterile pouch only in an appropriate clean working environment.
  2. Avoid touching the inner well surfaces and the inside of the lid.
  3. Pre-equilibrate culture medium when required by the validated protocol.
  4. Select working volume according to cell type, seeding density, incubation time and evaporation conditions.
  5. Use consistent pipetting depth and speed to reduce bubbles, splashing and well-to-well variation.
  6. Use the plate once only and dispose of it according to applicable laboratory procedures.

These recommendations are general guidance. Users should follow their validated cell-culture protocol and institutional biosafety procedures.

Sterility, Cleanliness and Quality Documentation

The plate is sterilized by gamma irradiation and individually sealed. Depending on the specification and order requirements, quality-control activities may include raw-material and appearance inspection, dimensional checks, surface-treatment consistency, packaging-integrity inspection, sterility validation, DNase/RNase testing, pyrogen or endotoxin evaluation and cell-attachment performance assessment.

If your purchasing specification requires a particular Sterility Assurance Level, endotoxin limit, Certificate of Analysis, Certificate of Conformance or other batch document, state the requirement before ordering. Puretest will confirm which limits and documents apply to the quoted product and production lot.

Storage, Shelf Life and Package Inspection

  • Storage temperature: 5-30°C.
  • Storage environment: Keep dry and away from direct sunlight and excessive heat.
  • Shelf life: 3 years from manufacture when stored in unopened original packaging.
  • Before use: Do not use if the sterile pouch is opened, punctured, wet or damaged.
  • Traceability: Check the applicable lot number and expiry information on the pouch or carton label.

Packaging, International Shipping and Supply Support

Each plate is individually sealed for convenient single-plate access. Inner-pack quantity, case quantity, carton dimensions, gross weight, MOQ and lead time are confirmed in the quotation. Export cartons are prepared to help protect products from compression and packaging damage during transportation.

Orders can be arranged by courier, air or sea according to delivery urgency, destination and volume. Samples can be requested for handling, cell-attachment and assay evaluation.

OEM, Private Label and Distributor Programs

Subject to order quantity and technical review, available services may include private-label sterile pouches and cartons, customized labels and barcodes, customer catalog numbers, tailored pack quantities, branded instruction sheets, multilingual packaging, batch documentation and long-term distributor supply planning.

For an OEM proposal, provide the target market, estimated annual volume, packaging language, delivery schedule and documentation requirements.

Choosing the Right Cell Culture Plate Format

Format Relative Culture Area Reagent Use Typical Use
6-well Largest Highest Expansion, coverslips, scraping and higher-yield collection
12-well Medium-large Medium Transfection, staining, optimization and sample preparation
24-well Medium Medium-low Multi-condition assays, microscopy and dose-response studies
48-well Small Low Screening, optimization and replicate-heavy studies
96-well Smallest Lowest Higher-throughput cell assays and parallel screening

Frequently Asked Questions

Why choose a 48-well plate?

It doubles the condition capacity of a 24-well plate while retaining more manual access and well area than a 96-well plate.

What working volume should I use?

Approximately 0.19-0.285 mL per well is a typical starting range. Optimize volume for the cell type, incubation time and evaporation conditions.

Is the plate suitable for multichannel pipetting?

The 6 x 8 layout can support compatible multichannel workflows. Confirm channel spacing, tip position and protocol parameters before routine use.

Is the plate suitable for suspension cells?

The TC-treated surface is primarily designed for adherent cells. Ask Puretest whether a non-treated or specialized surface is more appropriate.

Can the plate be used for microscopy?

The clear flat bottoms support routine microscopy and imaging. Confirm instrument optics and focal requirements before ordering.

Can I request samples for assay development?

Yes. Include the cell type, assay, quantity and destination country with the sample request.

Is a Certificate of Analysis available?

Applicable batch and quality documents can be provided according to the quoted product and order requirements. Confirm the required list before ordering.

Can the packaging carry our own brand?

Private-label packaging, labels, barcodes, instruction sheets and carton markings can be discussed for eligible volume orders.

Request a Sample, Technical Document or Quotation

Tell us your cell type, intended workflow, annual quantity, destination country and packaging requirements. Contact Puretest for a sample, current technical drawing, applicable quality documentation or commercial quotation.

RELATED PRODUCTS

White breathable heat sealing film roll with a brown core and an unrolled membrane section
Breathable Heat Sealing Film
Transparent heat sealing film roll with a white core and clear unrolled film
Clear Heat Sealing Film
Roll of aluminum heat sealing foil with an unrolled silver foil section
Aluminum Heat Sealing Foil
Single pipette tip accessing a microplate well through a cross-shaped pre-slit sealing film opening
Pierceable and Pre-Slit Microplate Sealing Film
GET IN TOUCH

Contact Us

General Inquiries​

Leave info for details

Please leave your message here! We willsend detailed technical info and quotationto you!