A fixed-volume single-channel pipette family for straightforward repeated dispensing. Each instrument is dedicated to one nominal volume, making it useful for a defined aliquoting step; the removable lower components support servicing and approved component-level autoclaving.
Request a sample, specification sheet or quotation
MANUAL LIQUID HANDLING | SINGLE-CHANNEL | FIXED VOLUME
A fixed-volume single-channel pipette family for straightforward repeated dispensing. Each instrument is dedicated to one nominal volume, making it useful for a defined aliquoting step; the removable lower components support servicing and approved component-level autoclaving.
| Design feature | Function and practical benefit |
|---|---|
| Plunger and finger support | The manual thumb control and shaped finger rest support a stable grip during repeated aspiration and dispensing. |
| Fixed-volume identification | The instrument is dedicated to its marked nominal volume. Changing the required transfer volume means selecting another fixed-volume model. |
| Tip cone and ejector | The nozzle accepts the correctly matched disposable tip; the ejector releases a used tip without needing to pull it off by hand. |
| Removable components | Serviceable components allow inspection and maintenance following the supplied instructions. Recheck performance after servicing. |
| Autoclaving scope | Designated lower components only. Do not autoclave the complete handle. |
| Specification | Configuration |
|---|---|
| Product family | Partially Autoclavable Single-Channel Fixed-Volume Pipette |
| Operation | Manual, fixed volume |
| Channel count | 1 |
| Volume options | 5–5,000 µL; see the individual options below |
| Autoclaving scope | Designated lower components only. Do not autoclave the complete handle. |
| Tip selection | Match the pipette range and cone geometry; verify sealing with the selected tip. |
| Power requirement | Manual operation; no battery or charger required. |
| Supply format | Individual range models; request the packing configuration with your quotation. |
Options are listed from small to large. Each row represents an individual instrument model; all volume values are in microliters (µL).
| Nominal volume | Format | Selection note |
|---|---|---|
| 5 µL | Single channel | Dedicated nominal volume; not user-adjustable. |
| 10 µL | Single channel | Dedicated nominal volume; not user-adjustable. |
| 20 µL | Single channel | Dedicated nominal volume; not user-adjustable. |
| 25 µL | Single channel | Dedicated nominal volume; not user-adjustable. |
| 50 µL | Single channel | Dedicated nominal volume; not user-adjustable. |
| 100 µL | Single channel | Dedicated nominal volume; not user-adjustable. |
| 200 µL | Single channel | Dedicated nominal volume; not user-adjustable. |
| 250 µL | Single channel | Dedicated nominal volume; not user-adjustable. |
| 500 µL | Single channel | Dedicated nominal volume; not user-adjustable. |
| 1,000 µL | Single channel | Dedicated nominal volume; not user-adjustable. |
| 2,000 µL | Single channel | Dedicated nominal volume; not user-adjustable. |
| 5,000 µL | Single channel | Dedicated nominal volume; not user-adjustable. |
Images show representative instruments within this design family. Nozzle dimensions and markings can vary with the selected volume. Confirm the exact range and configuration on your quotation.
Repetitive reagent addition, routine aliquoting, standardized sample preparation, training and dedicated fixed-volume laboratory tasks.
Choose this family for a repeated nominal volume when component-level autoclaving meets your workflow requirements.
For a laboratory set, combine instruments around the volumes you actually use. A low-volume transfer, a routine reagent addition and a milliliter-scale buffer step may call for different ranges and different tips.
No. Each fixed-volume model is dedicated to its listed nominal volume. Choose a different fixed model or an adjustable pipette if your method requires other volumes.
No. Only the designated lower components are intended for autoclaving. The upper handle is not included in the autoclaving scope.
Not necessarily. Capacity, cone geometry and sealing must match. Ask for a tip recommendation and evaluate the chosen pipette-tip combination before a larger order.
Request the calibration or performance document for the exact supplied model and volume range. Results and acceptance criteria should correspond to that configuration, its test volumes and the tips used.
Send your required ranges, quantities, intended market and branding or packaging requirements. Puretest can review the proposed configuration and discuss samples and quotation details before you commit to an order.
Tell us the nominal volume, tip format, quantity and cleaning requirements. For OEM projects, include your logo, packaging brief and destination market so we can prepare a relevant proposal.