Fully Autoclavable 12-Channel Magnetic Pipette

A twelve-channel manual pipette in the magnetic-version design for row-wise microplate workflows. Twelve aligned channels dispense the selected volume in parallel, while the fully autoclavable construction supports laboratories that include the complete instrument in their approved decontamination process.

  • 4 volume-range options: 0.5–300 µL across separate models.
  • 12-channel head: parallel transfers for compatible standard 96-well plate layouts.
  • Fully autoclavable: whole-instrument treatment according to the supplied instructions.
  • Bench-friendly controls: thumb plunger, finger support and a tip-ejection control.

Request a sample, specification sheet or quotation

PRODUCT DETAILS

MANUAL LIQUID HANDLING | 12-CHANNEL | ADJUSTABLE VOLUME

A twelve-channel manual pipette in the magnetic-version design for row-wise microplate workflows. Twelve aligned channels dispense the selected volume in parallel, while the fully autoclavable construction supports laboratories that include the complete instrument in their approved decontamination process.

Product Highlights

  • 4 volume-range options: 0.5–300 µL across separate models.
  • 12-channel head: parallel transfers for compatible standard 96-well plate layouts.
  • Fully autoclavable: whole-instrument treatment according to the supplied instructions.
  • Bench-friendly controls: thumb plunger, finger support and a tip-ejection control.
  • OEM enquiries: discuss range selection, tip fit, branding and packaging with Puretest.

Pipette Structure and Functional Design

Design feature Function and practical benefit
Plunger and finger support The manual thumb control and shaped finger rest support a stable grip during repeated aspiration and dispensing.
Volume-setting window The front window displays the selected setting. Adjust only within the range marked on the individual instrument.
12-position head 12 aligned positions support simultaneous transfers. Fit compatible tips evenly and verify sealing across every channel before starting the plate.
Magnetic-version configuration This page covers the magnetic-version manual pipette shown in the images. It is not a magnetic-bead extraction instrument; specify this configuration when requesting samples or replacement components.
Removable components Serviceable components allow inspection and maintenance following the supplied instructions. Recheck performance after servicing.
Autoclaving scope Complete instrument, using the supplied approved autoclaving instructions.

Technical Overview

Specification Configuration
Product family Fully Autoclavable 12-Channel Magnetic Pipette
Operation Manual, adjustable volume
Channel count 12
Volume options 0.5–300 µL; see the individual options below
Plate layout Twelve positions align with a row of a standard 96-well plate.
Autoclaving scope Complete instrument, using the supplied approved autoclaving instructions.
Tip selection Match the pipette range and cone geometry; verify sealing with the selected tip.
Power requirement Manual operation; no battery or charger required.
Supply format Individual range models; request the packing configuration with your quotation.

Volume-Range Options

Options are listed from small to large. Each row represents an individual instrument model; all volume values are in microliters (µL).

Adjustable volume range Format Selection note
0.5–10 µL 12 channels Select this range as an individual pipette model.
5–50 µL 12 channels Select this range as an individual pipette model.
10–100 µL 12 channels Select this range as an individual pipette model.
50–300 µL 12 channels Select this range as an individual pipette model.

Images show representative instruments within this design family. Nozzle dimensions and markings can vary with the selected volume. Confirm the exact range and configuration on your quotation.

Applications and Workflow Fit

Row-wise ELISA setup, PCR plate reagent distribution, cell-based assay preparation and repeated additions across twelve positions of a compatible 96-well plate.

Choose twelve channels when your method, reagent arrangement and sample map are organized around a complete twelve-well row.

On a standard 96-well plate, the twelve-channel format follows positions 1–12 across a row. Plan the plate map and reagent reservoir together so each tip has adequate access to liquid. Channel count does not replace a method-specific fit and performance check.

How to Select the Right Pipette

  1. List your routine transfer volume first, then select an individual range that contains it. A family-wide minimum and maximum do not describe one universal instrument.
  2. Check that 12 channels suit your sample map and that the plate, reagent reservoir and tip rack fit your workflow.
  3. Choose fully autoclavable construction when your procedure calls for treating the complete instrument, and follow the supplied cycle and preparation instructions.
  4. For purchasing or qualification, request the model-specific increment and calibration data for the exact supplied configuration and your required working volumes.

Handling, Cleaning and Maintenance

  • Inspect the instrument and fit clean, correctly matched tips before use. For multichannel work, check seating and liquid levels at every position.
  • Use a consistent plunger speed, immersion depth and dispensing technique appropriate to the liquid and the supplied operating instructions.
  • Prevent liquid from entering the handle. Store the instrument upright when not in use and replace tips between samples as your procedure requires.
  • Autoclave the instrument only under the conditions in its supplied instructions. Allow it to cool and dry before reassembly or use, as applicable.
  • Inspect seals and moving parts as part of routine maintenance. Arrange a performance check after servicing, an impact or suspected leakage.

Frequently Asked Questions

Does one pipette cover the complete family range?

No. Each listed range is a separate instrument option. Select the model that matches your working volume; do not adjust an instrument beyond its own marked limits.

Can the complete instrument be autoclaved?

This is the fully autoclavable family. Use the preparation, cycle, drying and maintenance instructions supplied with the exact model; do not substitute a generic cycle.

Should I choose eight or twelve channels?

Use eight channels for groups arranged down a standard 96-well plate column and twelve for groups across a row. Also check the reservoir, tip rack and labware used by your method.

Where can I find accuracy and precision data?

Request the calibration or performance document for the exact supplied model and volume range. Results and acceptance criteria should correspond to that configuration, its test volumes and the tips used.

Can Puretest support private-label enquiries?

Send your required ranges, quantities, intended market and branding or packaging requirements. Puretest can review the proposed configuration and discuss samples and quotation details before you commit to an order.

Build Your Pipette Enquiry

Tell us the volume range, channel count, tip format, quantity and cleaning requirements. For OEM projects, include your logo, packaging brief and destination market so we can prepare a relevant proposal.

Request a Pipette Quotation

RELATED PRODUCTS

Fully Autoclavable 8-Channel Magnetic Pipette, complete instrument on a white background
Fully Autoclavable 8-Channel Magnetic Pipette
Fully Autoclavable 8-Channel Pipette, complete instrument on a white background
Fully Autoclavable 8-Channel Pipette
Fully Autoclavable Single-Channel Adjustable Pipette, complete instrument on a white background
Fully Autoclavable Single-Channel Adjustable Pipette
Fully Autoclavable Single-Channel Fixed-Volume Pipette, complete instrument on a white background
Fully Autoclavable Single-Channel Fixed-Volume Pipette