A twelve-channel manual pipette in the magnetic-version design for row-wise microplate workflows. Twelve aligned channels dispense the selected volume in parallel, while the fully autoclavable construction supports laboratories that include the complete instrument in their approved decontamination process.
Request a sample, specification sheet or quotation
MANUAL LIQUID HANDLING | 12-CHANNEL | ADJUSTABLE VOLUME
A twelve-channel manual pipette in the magnetic-version design for row-wise microplate workflows. Twelve aligned channels dispense the selected volume in parallel, while the fully autoclavable construction supports laboratories that include the complete instrument in their approved decontamination process.
| Design feature | Function and practical benefit |
|---|---|
| Plunger and finger support | The manual thumb control and shaped finger rest support a stable grip during repeated aspiration and dispensing. |
| Volume-setting window | The front window displays the selected setting. Adjust only within the range marked on the individual instrument. |
| 12-position head | 12 aligned positions support simultaneous transfers. Fit compatible tips evenly and verify sealing across every channel before starting the plate. |
| Magnetic-version configuration | This page covers the magnetic-version manual pipette shown in the images. It is not a magnetic-bead extraction instrument; specify this configuration when requesting samples or replacement components. |
| Removable components | Serviceable components allow inspection and maintenance following the supplied instructions. Recheck performance after servicing. |
| Autoclaving scope | Complete instrument, using the supplied approved autoclaving instructions. |
| Specification | Configuration |
|---|---|
| Product family | Fully Autoclavable 12-Channel Magnetic Pipette |
| Operation | Manual, adjustable volume |
| Channel count | 12 |
| Volume options | 0.5–300 µL; see the individual options below |
| Plate layout | Twelve positions align with a row of a standard 96-well plate. |
| Autoclaving scope | Complete instrument, using the supplied approved autoclaving instructions. |
| Tip selection | Match the pipette range and cone geometry; verify sealing with the selected tip. |
| Power requirement | Manual operation; no battery or charger required. |
| Supply format | Individual range models; request the packing configuration with your quotation. |
Options are listed from small to large. Each row represents an individual instrument model; all volume values are in microliters (µL).
| Adjustable volume range | Format | Selection note |
|---|---|---|
| 0.5–10 µL | 12 channels | Select this range as an individual pipette model. |
| 5–50 µL | 12 channels | Select this range as an individual pipette model. |
| 10–100 µL | 12 channels | Select this range as an individual pipette model. |
| 50–300 µL | 12 channels | Select this range as an individual pipette model. |
Images show representative instruments within this design family. Nozzle dimensions and markings can vary with the selected volume. Confirm the exact range and configuration on your quotation.
Row-wise ELISA setup, PCR plate reagent distribution, cell-based assay preparation and repeated additions across twelve positions of a compatible 96-well plate.
Choose twelve channels when your method, reagent arrangement and sample map are organized around a complete twelve-well row.
On a standard 96-well plate, the twelve-channel format follows positions 1–12 across a row. Plan the plate map and reagent reservoir together so each tip has adequate access to liquid. Channel count does not replace a method-specific fit and performance check.
No. Each listed range is a separate instrument option. Select the model that matches your working volume; do not adjust an instrument beyond its own marked limits.
This is the fully autoclavable family. Use the preparation, cycle, drying and maintenance instructions supplied with the exact model; do not substitute a generic cycle.
Use eight channels for groups arranged down a standard 96-well plate column and twelve for groups across a row. Also check the reservoir, tip rack and labware used by your method.
Request the calibration or performance document for the exact supplied model and volume range. Results and acceptance criteria should correspond to that configuration, its test volumes and the tips used.
Send your required ranges, quantities, intended market and branding or packaging requirements. Puretest can review the proposed configuration and discuss samples and quotation details before you commit to an order.
Tell us the volume range, channel count, tip format, quantity and cleaning requirements. For OEM projects, include your logo, packaging brief and destination market so we can prepare a relevant proposal.