An eight-channel manual pipette in the magnetic-version design, combining adjustable dispensing with fully autoclavable construction. The aligned channel head supports parallel additions across a column of a standard 96-well plate, helping keep repetitive plate setup organized.
Request a sample, specification sheet or quotation
MANUAL LIQUID HANDLING | 8-CHANNEL | ADJUSTABLE VOLUME
An eight-channel manual pipette in the magnetic-version design, combining adjustable dispensing with fully autoclavable construction. The aligned channel head supports parallel additions across a column of a standard 96-well plate, helping keep repetitive plate setup organized.
| Design feature | Function and practical benefit |
|---|---|
| Plunger and finger support | The manual thumb control and shaped finger rest support a stable grip during repeated aspiration and dispensing. |
| Volume-setting window | The front window displays the selected setting. Adjust only within the range marked on the individual instrument. |
| 8-position head | 8 aligned positions support simultaneous transfers. Fit compatible tips evenly and verify sealing across every channel before starting the plate. |
| Magnetic-version configuration | This page covers the magnetic-version manual pipette shown in the images. It is not a magnetic-bead extraction instrument; specify this configuration when requesting samples or replacement components. |
| Removable components | Serviceable components allow inspection and maintenance following the supplied instructions. Recheck performance after servicing. |
| Autoclaving scope | Complete instrument, using the supplied approved autoclaving instructions. |
| Specification | Configuration |
|---|---|
| Product family | Fully Autoclavable 8-Channel Magnetic Pipette |
| Operation | Manual, adjustable volume |
| Channel count | 8 |
| Volume options | 0.5–1,000 µL; see the individual options below |
| Plate layout | Eight positions align with a column of a standard 96-well plate. |
| Autoclaving scope | Complete instrument, using the supplied approved autoclaving instructions. |
| Tip selection | Match the pipette range and cone geometry; verify sealing with the selected tip. |
| Power requirement | Manual operation; no battery or charger required. |
| Supply format | Individual range models; request the packing configuration with your quotation. |
Options are listed from small to large. Each row represents an individual instrument model; all volume values are in microliters (µL).
| Adjustable volume range | Format | Selection note |
|---|---|---|
| 0.5–10 µL | 8 channels | Select this range as an individual pipette model. |
| 5–50 µL | 8 channels | Select this range as an individual pipette model. |
| 10–100 µL | 8 channels | Select this range as an individual pipette model. |
| 50–300 µL | 8 channels | Select this range as an individual pipette model. |
| 100–1,000 µL | 8 channels | Select this range as an individual pipette model. |
Images show representative instruments within this design family. Nozzle dimensions and markings can vary with the selected volume. Confirm the exact range and configuration on your quotation.
Column-wise PCR setup, ELISA reagent addition, serial dilution, assay development and other parallel transfers into compatible 96-well plates.
Choose this eight-channel magnetic-version family when your plate layout is organized in groups of eight and full-instrument autoclaving is required.
On a standard 96-well plate, the eight-channel format follows the A–H positions within a column. Plan the plate map and reagent reservoir together so each tip has adequate access to liquid. Channel count does not replace a method-specific fit and performance check.
No. Each listed range is a separate instrument option. Select the model that matches your working volume; do not adjust an instrument beyond its own marked limits.
This is the fully autoclavable family. Use the preparation, cycle, drying and maintenance instructions supplied with the exact model; do not substitute a generic cycle.
Use eight channels for groups arranged down a standard 96-well plate column and twelve for groups across a row. Also check the reservoir, tip rack and labware used by your method.
Request the calibration or performance document for the exact supplied model and volume range. Results and acceptance criteria should correspond to that configuration, its test volumes and the tips used.
Send your required ranges, quantities, intended market and branding or packaging requirements. Puretest can review the proposed configuration and discuss samples and quotation details before you commit to an order.
Tell us the volume range, channel count, tip format, quantity and cleaning requirements. For OEM projects, include your logo, packaging brief and destination market so we can prepare a relevant proposal.