An adjustable single-channel manual pipette family for flexible everyday liquid handling. Choose the individual range that matches your routine working volume, read the setting through the front window, and use the removable lower assembly for maintenance and approved autoclaving of the designated components.
Request a sample, specification sheet or quotation
MANUAL LIQUID HANDLING | SINGLE-CHANNEL | ADJUSTABLE VOLUME
An adjustable single-channel manual pipette family for flexible everyday liquid handling. Choose the individual range that matches your routine working volume, read the setting through the front window, and use the removable lower assembly for maintenance and approved autoclaving of the designated components.
| Design feature | Function and practical benefit |
|---|---|
| Plunger and finger support | The manual thumb control and shaped finger rest support a stable grip during repeated aspiration and dispensing. |
| Volume-setting window | The front window displays the selected setting. Adjust only within the range marked on the individual instrument. |
| Tip cone and ejector | The nozzle accepts the correctly matched disposable tip; the ejector releases a used tip without needing to pull it off by hand. |
| Removable components | Serviceable components allow inspection and maintenance following the supplied instructions. Recheck performance after servicing. |
| Autoclaving scope | Designated lower components only. Do not autoclave the complete handle. |
| Specification | Configuration |
|---|---|
| Product family | Partially Autoclavable Single-Channel Adjustable Pipette |
| Operation | Manual, adjustable volume |
| Channel count | 1 |
| Volume options | 0.1–20,000 µL; see the individual options below |
| Autoclaving scope | Designated lower components only. Do not autoclave the complete handle. |
| Tip selection | Match the pipette range and cone geometry; verify sealing with the selected tip. |
| Power requirement | Manual operation; no battery or charger required. |
| Supply format | Individual range models; request the packing configuration with your quotation. |
Options are listed from small to large. Each row represents an individual instrument model; all volume values are in microliters (µL).
| Adjustable volume range | Format | Selection note |
|---|---|---|
| 0.1–2.5 µL | Single channel | Select this range as an individual pipette model. |
| 0.5–10 µL | Single channel | Select this range as an individual pipette model. |
| 2–20 µL | Single channel | Select this range as an individual pipette model. |
| 5–50 µL | Single channel | Select this range as an individual pipette model. |
| 10–100 µL | Single channel | Select this range as an individual pipette model. |
| 20–200 µL | Single channel | Select this range as an individual pipette model. |
| 50–200 µL | Single channel | Select this range as an individual pipette model. |
| 100–1,000 µL | Single channel | Select this range as an individual pipette model. |
| 200–1,000 µL | Single channel | Select this range as an individual pipette model. |
| 500–5,000 µL | Single channel | Select this range as an individual pipette model. |
| 1,000–5,000 µL | Single channel | Select this range as an individual pipette model. |
| 1,000–10,000 µL | Single channel | Select this range as an individual pipette model. |
| 2,000–10,000 µL | Single channel | Select this range as an individual pipette model. |
| 2,000–20,000 µL | Single channel | Select this range as an individual pipette model. |
Images show representative instruments within this design family. Nozzle dimensions and markings can vary with the selected volume. Confirm the exact range and configuration on your quotation.
Sample transfers, PCR reagent setup, buffer preparation, analytical laboratory work, teaching and routine microliter-to-milliliter dispensing.
Choose this family when adjustable volume is needed and autoclaving of the approved lower components is sufficient for your laboratory procedures.
For a laboratory set, combine instruments around the volumes you actually use. A low-volume transfer, a routine reagent addition and a milliliter-scale buffer step may call for different ranges and different tips.
No. Each listed range is a separate instrument option. Select the model that matches your working volume; do not adjust an instrument beyond its own marked limits.
No. Only the designated lower components are intended for autoclaving. The upper handle is not included in the autoclaving scope.
Not necessarily. Capacity, cone geometry and sealing must match. Ask for a tip recommendation and evaluate the chosen pipette-tip combination before a larger order.
Request the calibration or performance document for the exact supplied model and volume range. Results and acceptance criteria should correspond to that configuration, its test volumes and the tips used.
Send your required ranges, quantities, intended market and branding or packaging requirements. Puretest can review the proposed configuration and discuss samples and quotation details before you commit to an order.
Tell us the volume range, tip format, quantity and cleaning requirements. For OEM projects, include your logo, packaging brief and destination market so we can prepare a relevant proposal.
General Inquiries
We use necessary cookies to run this website. With your permission, we also use analytics and optional visitor tools, including live chat and embedded maps. You can reject optional cookies and still browse products or send an enquiry. Change your choices anytime in Cookie settings.
Tell us the product, specifications and quantity you need. We’ll reply by email with the next steps.