A versatile manual pipette family for laboratories that change transfer volumes throughout the day and need a whole-instrument autoclaving option. Select individual models from low-microliter work through milliliter-scale reagent preparation; the front volume window keeps the chosen setting visible at the bench.
Request a sample, specification sheet or quotation
MANUAL LIQUID HANDLING | SINGLE-CHANNEL | ADJUSTABLE VOLUME
A versatile manual pipette family for laboratories that change transfer volumes throughout the day and need a whole-instrument autoclaving option. Select individual models from low-microliter work through milliliter-scale reagent preparation; the front volume window keeps the chosen setting visible at the bench.
| Design feature | Function and practical benefit |
|---|---|
| Plunger and finger support | The manual thumb control and shaped finger rest support a stable grip during repeated aspiration and dispensing. |
| Volume-setting window | The front window displays the selected setting. Adjust only within the range marked on the individual instrument. |
| Tip cone and ejector | The nozzle accepts the correctly matched disposable tip; the ejector releases a used tip without needing to pull it off by hand. |
| Removable components | Serviceable components allow inspection and maintenance following the supplied instructions. Recheck performance after servicing. |
| Autoclaving scope | Complete instrument, using the supplied approved autoclaving instructions. |
| Specification | Configuration |
|---|---|
| Product family | Fully Autoclavable Single-Channel Adjustable Pipette |
| Operation | Manual, adjustable volume |
| Channel count | 1 |
| Volume options | 0.1–20,000 µL; see the individual options below |
| Autoclaving scope | Complete instrument, using the supplied approved autoclaving instructions. |
| Tip selection | Match the pipette range and cone geometry; verify sealing with the selected tip. |
| Power requirement | Manual operation; no battery or charger required. |
| Supply format | Individual range models; request the packing configuration with your quotation. |
Options are listed from small to large. Each row represents an individual instrument model; all volume values are in microliters (µL).
| Adjustable volume range | Format | Selection note |
|---|---|---|
| 0.1–2.5 µL | Single channel | Select this range as an individual pipette model. |
| 0.5–10 µL | Single channel | Select this range as an individual pipette model. |
| 2–20 µL | Single channel | Standard and metal-nozzle configurations; specify the required version. |
| 5–50 µL | Single channel | Select this range as an individual pipette model. |
| 10–100 µL | Single channel | Select this range as an individual pipette model. |
| 20–200 µL | Single channel | Select this range as an individual pipette model. |
| 50–200 µL | Single channel | Select this range as an individual pipette model. |
| 100–1,000 µL | Single channel | Select this range as an individual pipette model. |
| 200–1,000 µL | Single channel | Select this range as an individual pipette model. |
| 500–5,000 µL | Single channel | Select this range as an individual pipette model. |
| 1,000–5,000 µL | Single channel | Select this range as an individual pipette model. |
| 1,000–10,000 µL | Single channel | Select this range as an individual pipette model. |
| 2,000–20,000 µL | Single channel | Select this range as an individual pipette model. |
Images show representative instruments within this design family. Nozzle dimensions and markings can vary with the selected volume. Confirm the exact range and configuration on your quotation.
PCR and qPCR reaction setup, nucleic-acid sample preparation, buffer addition, serial dilution and general reagent transfer.
Choose this family when both adjustable dispensing and whole-instrument decontamination are important to your workflow.
For a laboratory set, combine instruments around the volumes you actually use. A low-volume transfer, a routine reagent addition and a milliliter-scale buffer step may call for different ranges and different tips.
No. Each listed range is a separate instrument option. Select the model that matches your working volume; do not adjust an instrument beyond its own marked limits.
This is the fully autoclavable family. Use the preparation, cycle, drying and maintenance instructions supplied with the exact model; do not substitute a generic cycle.
Not necessarily. Capacity, cone geometry and sealing must match. Ask for a tip recommendation and evaluate the chosen pipette-tip combination before a larger order.
Request the calibration or performance document for the exact supplied model and volume range. Results and acceptance criteria should correspond to that configuration, its test volumes and the tips used.
Send your required ranges, quantities, intended market and branding or packaging requirements. Puretest can review the proposed configuration and discuss samples and quotation details before you commit to an order.