PRODUCTS

250 µL Robotic Pipette Tips Compatible with Agilent Bravo, 96-Format

250 µL robotic pipette tips for compatible Agilent Bravo automated liquid-handling workflows, supplied in 96-format rack configurations.

  • Detailed platform, head and rack selection guidance
  • Filter, sterility, conductivity and special-geometry options confirmed by SKU
  • Method-development and full-head qualification checklist
  • Samples, technical documents and OEM/private-label support

Request a compatibility sample or quotation

PRODUCT DETAILS

250 µL Agilent Bravo-Compatible Robotic Pipette Tips for Automated Liquid Handling

Puretest 250 µL robotic pipette tips are intended for general-purpose automated transfers across plate preparation, sample processing and reagent distribution. The page is structured for automation engineers, laboratory managers, procurement teams and distributors who need more than a generic statement that a tip “fits” an instrument.

This family is positioned for compatible Agilent Bravo workflows using a 96LT pipetting head and 96-format tip racks. Agilent platform literature associates the 250 µL family with an approximate 2–250 µL operating range. Final performance depends on the selected Puretest tip configuration, liquid class, source and destination labware and liquid properties.

Automated pipetting performance depends on the complete setup: platform, installed head or channel, tip cone interface, rack and carrier, software tip definition, liquid class, source vessel, destination labware and liquid properties. Puretest recommends sample qualification with the intended method before routine or validated use.

Product Highlights

  • Application-focused capacity: 250 µL family for general-purpose automated transfers across plate preparation, sample processing and reagent distribution.
  • Automation format: 96-format rack for compatible Agilent Bravo workflows.
  • Variant selection: filter, sterility, conductivity, special geometry and packaging are confirmed by SKU.
  • Method support: structured qualification checklist for fit, pickup, sealing, liquid class and full-head performance.
  • Documentation: current material, sterility, cleanliness and lot records can be requested for qualified configurations.
  • Supply: evaluation samples, international supply, distributor and OEM/private-label programs are available.

Tip Structure and Functional Design

A robotic tip must perform as part of a mechanical and fluidic system. Cone-interface consistency influences sealing and pressure behavior; shaft geometry affects access to labware; the distal section influences residual liquid and dispense behavior; and rack registration determines reliable multi-channel pickup. Filter placement, orifice size and conductive material can each change usable volume or liquid-class performance.

Qualification should therefore evaluate the exact sellable configuration rather than a family photograph alone. If a method changes from non-filtered to filtered, standard to wide-bore, clear to conductive or non-sterile to sterile supply, document the change and repeat the relevant fit and performance checks.

Technical Specifications and Selection Notes

Specification Current Family Profile Qualification / Ordering Note
Nominal family 250 µL Select according to critical transfer volumes and head configuration
Platform literature range Approximately 2–250 µL Platform reference only; customer qualification is required
Rack format 96-format Confirm carrier, rack height and lid clearance
Pipetting-head context Compatible Bravo 96LT workflows Provide the installed head and software method
Material Laboratory-grade polypropylene; exact color/configuration by SKU Confirm conductive requirement if applicable
Filter / sterile Configuration-dependent Confirm aerosol barrier, irradiation/wrapping and lot documents
Wide-bore May be available for suitable workflows Confirm orifice geometry and required sample type

Values referenced from platform literature describe the automation context, not a blanket performance guarantee for every Puretest SKU. Puretest will confirm the selected product configuration and available documents in the quotation.

Platform, Head and Rack Compatibility

This family is positioned for compatible Agilent Bravo workflows using a 96LT pipetting head and 96-format tip racks. Agilent platform literature associates the 250 µL family with an approximate 2–250 µL operating range. Final performance depends on the selected Puretest tip configuration, liquid class, source and destination labware and liquid properties.

Qualification Item Why It Matters Recommended Check
Platform and pipetting head The same brand may use different heads, channels and tip definitions Provide exact platform, head/pod/channel and software method
Rack and carrier Footprint, height and registration affect pickup Check carrier, deck coordinates, lid clearance and rack seating
Pickup and seal Seal quality affects pressure, accuracy and retention Verify all active channels for pickup, straightness, seal and ejection
Liquid class Viscosity, volatility, surface tension and foaming affect performance Optimize speed, delay, immersion depth, pre-wet, air gaps and tip touch
Critical volumes Nominal family names do not guarantee every transfer point Test minimum, routine and maximum critical method volumes
Variant change Filter, wide-bore, conductivity and material alter behavior Qualify every materially different configuration

For second-source qualification, provide the exact platform, installed head/pod/channel, current tip reference or drawing when available, rack/carrier, target volumes, liquids, filter and sterility needs and annual consumption. This reduces the risk of selecting a tip based on brand name alone.

Available Material, Filter and Packaging Configurations

Configuration Typical Reason to Select What to Confirm
Standard non-filtered Routine aqueous transfer and maximum internal-volume flexibility Confirm sterility and rack configuration
Filtered Aerosol-barrier or contamination-sensitive methods Usable volume and filter material are SKU-dependent
Sterile Contamination-controlled workflows Confirm irradiation, wrapping and current lot documents
Wide-bore Cells, beads or shear-sensitive samples Validate retention, orifice and liquid class

Not every option is necessarily available in every volume and rack combination. The final quotation should identify material, conductivity, filter state, sterility, rack format, wrapping, case quantity and required technical documents.

Typical Applications

  • 96-well plate filling
  • serial dilution
  • sample transfer and aliquoting
  • reagent and buffer dispensing
  • nucleic-acid workflow preparation

For general-purpose transfers, optimize aspiration and dispense speed, air gaps, delays, immersion depth, tip touch and mixing cycles for the actual reagent and plate geometry. Wide-bore and filtered variants may require different liquid classes.

Method Development and Qualification Workflow

  1. Verify mechanical fit: inspect rack seating, pickup, vertical alignment, seal, retention and ejection across all active channels.
  2. Verify deck integration: confirm carrier, rack height, lid clearance, pickup coordinates and access from required positions.
  3. Configure sensing: confirm whether conductive liquid-level detection or another detection strategy is required.
  4. Optimize the liquid class: evaluate aspiration/dispense speeds, delays, immersion depth, pre-wetting, air gaps, mixing and tip touch.
  5. Challenge real liquids: include aqueous, viscous, volatile, foaming, particulate or low-surface-tension liquids used by the actual process.
  6. Measure performance: verify accuracy, precision, residual volume, channel consistency, carryover risk and error recovery.
  7. Record the approved setup: document tip SKU, lot, rack, platform/head and liquid-class version for change control.

Quality, Sterility and Technical Documentation

Automation consumables may require product specifications, material information, irradiation or sterility records, lot traceability, certificate of analysis and RNase/DNase or pyrogen/endotoxin declarations. Availability and limits depend on the exact SKU and current production configuration.

Do not transfer a claim from another volume, material or package format. State the required documents in the RFQ so Puretest can confirm the applicable specification before order placement. Customers remain responsible for final qualification in regulated or validated workflows.

Packaging, Logistics and Supply Continuity

Racked robotic tips can be supplied in configurations appropriate to the selected platform and market. Confirm rack footprint, lid, wrapping, sterile state, label, barcode or lot-data needs, case quantity and pallet/carton requirements. Supply planning can include evaluation lots, production batches, annual forecasts and safety stock.

For international orders, provide delivery country, forecast, preferred shipping terms if known and any required import or technical documents. Configuration, minimum order quantity and lead time will be confirmed during quotation.

Selecting the Correct Tip within the Agilent Bravo Family

Agilent Bravo tip families commonly include 10, 30, 70 and 250 µL capacities. Select the smallest capacity that comfortably covers the validated method range and match the rack format to the installed head and carrier.

Choose the smallest capacity that comfortably covers the validated transfer range, but match capacity to the installed head and rack format. A protocol spanning substantially different volumes may benefit from more than one tip family.

International, Distributor and OEM Support

Puretest supports laboratories, automation integrators, distributors and private-label buyers serving Europe, North America and other international markets. Programs can cover evaluation samples, annual demand, safety stock, carton configuration, labels, artwork, lot information and shipping documents.

OEM/private-label availability is subject to configuration, minimum order quantity, forecast, artwork and lead-time review. Compatibility should remain accurately described; private labeling does not remove the need for customer-side method qualification.

Frequently Asked Questions

Are these original Agilent Bravo tips?

No. They are Puretest-manufactured robotic pipette tips designed for compatibility with specified Agilent Bravo workflows. Puretest is not affiliated with or endorsed by the instrument manufacturer.

Does the 250 µL family name guarantee the full usable range?

No. Usable range depends on platform, head/channel, filter, internal geometry, liquid class and application. Use the family as a selection starting point and validate critical transfer volumes.

How do I confirm platform compatibility?

Provide the exact instrument, installed head/pod/channel, rack/carrier and current tip reference when available. Test a sample for pickup, sealing, ejection and liquid-handling performance.

Are filtered and sterile versions available?

Availability is configuration-dependent. State filter, sterility, wrapping and required documents in the RFQ so the exact SKU can be confirmed.

Can a filtered tip use the same liquid class as a non-filtered tip?

Do not assume so. A filter changes usable internal space and may affect fluid behavior. Qualify the filtered configuration separately.

Are conductive tips required?

Only when the validated method uses a compatible conductive liquid-level-detection strategy or another requirement specifies conductive material. Confirm platform hardware and method settings.

Can we receive samples before a production order?

Yes. Sample evaluation is recommended before routine use, especially for a new method or second-source qualification.

What information speeds up a quotation?

Send platform, head/pod/channel, target volumes, liquids, filter, sterility, conductivity, rack, documents, annual quantity and delivery country.

Request a Compatibility Sample, Technical Document or Quotation

Send your Agilent Bravo platform and head configuration, 250 µL requirement, rack format, filter, sterility, conductivity or special-geometry needs, required documents, expected annual quantity and delivery country. Puretest will confirm the closest sellable configuration and sample plan.

Contact Puretest for a sample, technical document or quotation

Trademark notice: Agilent and Bravo are trademarks or registered trademarks of their respective owner. Puretest is not affiliated with or endorsed by the instrument manufacturer. Compatibility references identify intended instrument use only.

RELATED PRODUCTS

2.3 mL 96-well diamond-bottom deep well plate
2.3 mL 96-Well Diamond-Bottom Deep Well Plate
high-density robotic pipette tip rack compatible with Tecan Fluent MCA 384 automation
Robotic Pipette Tips Compatible with Tecan MCA 384, 15–500 µL
1000 µL robotic pipette tip rack compatible with Tecan Fluent MCA 96 automation
1000 µL Robotic Pipette Tips Compatible with Tecan MCA 96
P1000 clear large-volume robotic pipette tip compatible with Beckman Biomek automation
P1000 Robotic Pipette Tips Compatible with Beckman Biomek
GET IN TOUCH

Contact Us

General Inquiries​

Leave info for details

Please leave your message here! We willsend detailed technical info and quotationto you!