PRODUCTS

70 µL Robotic Pipette Tips Compatible with Agilent Bravo, 384-Format

70 µL Robotic Pipette Tips Compatible with Agilent Bravo, 384-Format for compatible automated liquid-handling workflows.

  • Platform, head and rack selection guidance
  • Technical specification and configuration tables
  • Full-head qualification workflow
  • Samples, technical documents and international supply support

Request a compatibility sample or quotation

PRODUCT DETAILS

70 µL Robotic Pipette Tips Compatible with Agilent Bravo, 384-Format

Puretest 70 µL robotic pipette tips are intended for high-density plate preparation, serial dilution and intermediate-volume reagent transfer. This page is structured for automation engineers, laboratory managers, procurement teams, distributors and OEM buyers who need an auditable selection process rather than a generic statement that a tip “fits.”

Agilent platform literature associates the 70 µL family with an approximate 0.75–70 µL transfer range and 96ST or 384ST pipetting-head workflows. The 70 µL family may be supplied in a 384-position rack context. Exact material, filter, sterility, conductive and special-geometry options remain SKU-dependent.

Reliable automated pipetting depends on the complete system: instrument, installed head or channel, tip-cone interface, rack, carrier, software tip definition, liquid class, source and destination labware and liquid properties. Puretest recommends sample qualification with the intended method before routine or validated use.

Product Highlights

  • Application-focused family: 70 µL selection for high-density plate preparation, serial dilution and intermediate-volume reagent transfer.
  • Automation format: 384-format rack for compatible Agilent Bravo workflows.
  • Transparent option control: filter, sterility, conductivity, special geometry and packaging are confirmed by exact SKU.
  • Full-head qualification: structured checks for rack seating, pickup, seal, liquid class, channel consistency and ejection.
  • Document support: current material, cleanliness, sterility and lot records can be requested for qualified configurations.
  • Commercial support: evaluation samples, international supply, distributor and OEM/private-label programs are available.

Tip Structure and Functional Design

A robotic pipette tip functions as part of a mechanical and fluidic system. Cone-interface consistency influences sealing and pressure behavior; shaft geometry affects labware access; the distal section influences residual liquid and dispense behavior; and rack registration determines multi-channel pickup reliability. Filter placement, orifice geometry and material can each change usable volume or liquid-class performance.

Qualification must therefore use the exact sellable configuration. A change from non-filtered to filtered, standard to extended or wide-bore, clear to conductive, or non-sterile to sterile supply should be documented and the relevant mechanical and liquid-handling checks repeated.

Technical Specifications and Selection Notes

Specification Family / Platform Context Qualification or Ordering Note
Nominal family 70 µL Suitable for intermediate-volume high-density workflows
Platform literature range Approximately 0.75–70 µL Reference context only; validate critical method volumes
Rack density 384-format Confirm deck carrier, rack height, lid and pickup coordinates
Head context Compatible Bravo 96ST / 384ST workflows Provide the installed head and software method
Material / sensing Clear or conductive configuration by SKU Confirm the liquid-level-detection strategy
Filter / sterile Configuration-dependent Filtered usable volume and sterility documents must be confirmed
Wide-bore / special geometry May be available for selected configurations Confirm sample type, orifice and retention requirements

Platform-literature values describe the compatible automation context; they do not create a universal Puretest performance guarantee. Puretest will confirm the actual quoted configuration, available documents and sample plan.

Platform, Head and Rack Compatibility

Agilent platform literature associates the 70 µL family with an approximate 0.75–70 µL transfer range and 96ST or 384ST pipetting-head workflows. The 70 µL family may be supplied in a 384-position rack context. Exact material, filter, sterility, conductive and special-geometry options remain SKU-dependent.

Qualification Item Why It Matters Recommended Check
Instrument and head One platform family may support multiple heads and tip definitions Provide the exact platform, installed head/pod and software method
Rack and carrier Footprint, height and registration determine reliable pickup Confirm carrier, deck coordinates, lid clearance and rack seating
Pickup, seal and ejection Mechanical consistency affects pressure, retention and error rate Inspect every active channel across representative deck positions
Liquid class Viscosity, volatility, surface tension and foaming change transfer behavior Tune speeds, delays, immersion depth, pre-wetting, air gaps and tip touch
Critical transfer points A nominal family does not guarantee every method volume Test minimum, routine and maximum critical volumes with real liquids
Variant changes Filters, material, geometry and sterility can alter behavior Requalify each materially different sellable configuration

For second-source qualification, send the exact platform, installed head or pod, current tip reference or drawing when available, rack carrier, target volumes, liquids, filter and sterility needs and annual consumption.

Available Material, Filter and Packaging Configurations

Configuration Typical Reason to Select What to Confirm
Clear / non-conductive Routine visual workflows Filter, sterility and rack configuration
Conductive Compatible sensing workflows Hardware support and method settings
Filtered Contamination-sensitive methods Filter material and effective capacity
Wide-bore Cells, beads or shear-sensitive samples Orifice size, retention and liquid class

Not every option is necessarily available in every volume and rack combination. The final quotation should identify material, conductivity, filter state, sterility, rack format, wrapping, case quantity and required technical documents.

Typical Applications

  • 384-well plate preparation
  • serial dilution
  • assay reagent addition
  • sample normalization
  • screening workflow setup

The 70 µL class bridges miniaturized and routine transfers. Test the lowest critical volume, routine operating point and upper transfer limit with representative liquids, then record the approved liquid class and tip SKU together.

Method Development and Qualification Workflow

  1. Verify mechanical fit: inspect rack seating, pickup, vertical alignment, seal, retention and ejection across all active channels.
  2. Verify deck integration: confirm carrier, rack height, lid clearance, pickup coordinates and access from required positions.
  3. Configure sensing: confirm whether conductive liquid-level detection or another detection strategy is required.
  4. Optimize the liquid class: evaluate aspiration and dispense speeds, delays, immersion depth, pre-wetting, air gaps, mixing and tip touch.
  5. Challenge real liquids: include aqueous, viscous, volatile, foaming, particulate or low-surface-tension liquids used by the process.
  6. Measure performance: verify accuracy, precision, residual volume, channel consistency, carryover risk and error recovery.
  7. Record the approved setup: document tip SKU, lot, rack, instrument/head and liquid-class version for change control.

Quality, Sterility and Technical Documentation

Automation consumables may require material information, product specifications, irradiation or sterility records, lot traceability, certificate of analysis and RNase/DNase or pyrogen/endotoxin declarations. Availability and limits depend on the exact SKU and current production configuration.

Do not transfer a claim from another capacity, material or package format. State required documents in the RFQ so Puretest can confirm what applies before order placement. Customers remain responsible for final qualification in regulated or validated workflows.

Packaging, Logistics and Supply Continuity

Racked robotic tips can be supplied in configurations appropriate to the selected platform and market. Confirm rack footprint, lid, wrapping, sterile state, label, barcode or lot-data needs, case quantity and pallet/carton requirements. Supply planning may include evaluation lots, production batches, annual forecasts and safety stock.

For international orders, provide delivery country, annual or monthly demand and required import or technical documents. Configuration, minimum order quantity and lead time are confirmed during quotation.

Selecting the Correct Tip within the Agilent Bravo Family

Bravo-compatible selection commonly spans 10, 30, 70 and 250 µL families. Use the smallest family that comfortably covers the validated method, while keeping head, rack density and special options aligned.

Choose the smallest capacity that comfortably covers the validated transfer range, while matching the installed head and rack format. A protocol spanning substantially different volumes may benefit from more than one tip family.

RFQ Information Checklist

Information to Send Example Why It Helps
Platform and installed head Agilent Bravo Prevents selection by brand name alone
Target transfer range 70 µL Supports capacity and filter-state selection
Rack / carrier 384-format rack Confirms footprint, density and pickup geometry
Liquid characteristics Aqueous, viscous, volatile, foaming, cells or beads Guides geometry and qualification planning
Required options Filter, sterile, conductive, nested or special geometry Defines the exact quotation variant
Commercial details Annual quantity, delivery country and required documents Supports MOQ, lead time and logistics review

A complete RFQ enables Puretest to recommend a specific sellable configuration and reduces sample cycles, especially when multiple rack or filter variants exist under the same nominal capacity.

International, Distributor and OEM Support

Puretest supports laboratories, automation integrators, distributors and private-label buyers serving Europe, North America and other international markets. Programs can cover evaluation samples, annual demand, safety stock, carton configuration, labels, artwork, lot information and shipping documents.

OEM/private-label availability is subject to configuration, minimum order quantity, forecast, artwork and lead-time review. Private labeling does not remove the need for customer-side compatibility and method qualification.

Frequently Asked Questions

Are these original Agilent Bravo tips?

No. They are Puretest-manufactured robotic pipette tips designed for compatibility with specified Agilent Bravo workflows. Puretest is not affiliated with or endorsed by the instrument manufacturer.

Does the 70 µL family name guarantee every transfer point?

No. Usable performance depends on platform, head or channel, filter, internal geometry, liquid class and application. Use the family as a selection starting point and validate critical transfers.

How do I confirm platform compatibility?

Provide the exact instrument, installed head or pod, rack/carrier and current tip reference when available. Test a sample for pickup, sealing, ejection and liquid-handling performance.

Are filtered and sterile versions available?

Availability is configuration-dependent. State filter, sterility, wrapping and required documents in the RFQ so the exact sellable configuration can be confirmed.

Can a filtered tip use the same liquid class as a non-filtered tip?

Do not assume so. A filter changes usable internal space and can affect fluid behavior. Qualify the filtered configuration separately.

Are conductive tips required?

Only when the validated method uses a compatible conductive liquid-level-detection strategy or another requirement specifies conductive material. Confirm hardware and method settings.

Can we receive samples before a production order?

Yes. Sample evaluation is recommended before routine use, particularly for a new method or second-source qualification.

What information speeds up a quotation?

Send platform, installed head or pod, target volumes, liquids, filter, sterility, conductivity, rack, documents, annual quantity and delivery country.

Request a Compatibility Sample, Technical Document or Quotation

Send your Agilent Bravo platform and head configuration, 70 µL requirement, rack format, filter, sterility, conductivity or special-geometry needs, required documents, expected annual quantity and delivery country. Puretest will confirm the closest sellable configuration and sample plan.

Contact Puretest for a sample, technical document or quotation

Trademark notice: Agilent and Bravo are trademarks or registered trademarks of their respective owner. Puretest is not affiliated with or endorsed by the instrument manufacturer. Compatibility references identify intended instrument use only.

RELATED PRODUCTS

high-density robotic pipette tip rack compatible with Tecan Fluent MCA 384 automation
Robotic Pipette Tips Compatible with Tecan MCA 384, 15–500 µL
1000 µL robotic pipette tip rack compatible with Tecan Fluent MCA 96 automation
1000 µL Robotic Pipette Tips Compatible with Tecan MCA 96
P1000 clear large-volume robotic pipette tip compatible with Beckman Biomek automation
P1000 Robotic Pipette Tips Compatible with Beckman Biomek
P30 and longer P30XL robotic pipette tips compatible with Beckman Biomek automation
P30 & P30XL Robotic Pipette Tips Compatible with Beckman Biomek
GET IN TOUCH

Contact Us

General Inquiries​

Leave info for details

Please leave your message here! We willsend detailed technical info and quotationto you!