PRODUCTS

60 mL Urine Collection System

60 mL polypropylene urine collection cups with covered yellow transfer caps, offered with matching evacuated urine-tube configurations. Select the pickup design, tube-bottom format and packing for your laboratory workflow.

PRODUCT DETAILS

60 mL Urine Collection System

60 mL polypropylene urine collection cups with covered yellow transfer caps, offered with matching evacuated urine-tube configurations. Select the pickup design, tube-bottom format and packing for your laboratory workflow.

Product Highlights

  • 60 mL nominal cup capacity; the paired tube has a separate 10 mL reference capacity.
  • Covered cap-mounted transfer port with a matching pickup assembly.
  • Two pickup configurations with configuration-specific packing.
  • U-bottom and V-bottom PET tube formats for selection.

Structure and Functional Design

Two yellow-cap collection formats combine a tapered cup with a covered transfer port and a cap-mounted pickup assembly. The external and internal pickup versions have different cup dimensions and packing configurations.

Technical Specifications

Parameter Selection specification
Nominal capacity 60 mL
Product type Urine Collection System
Closure Yellow screw cap with covered transfer port
Body material PP
Sterility Specify required sterile or non-sterile configuration at inquiry; not determined by cap color
Paired tube reference PET; 10 mL; 16 × 100 mm; U-bottom or V-bottom
Cup fill-volume reference 25–45 mL; confirm with the supplied system instructions

Configuration Options

Configuration Body material Reference diameter × height Closure / sampling tool
External pickup configuration PP 54 × 64 mm Yellow transfer cap
Internal pickup configuration PP 52 × 64 mm Yellow transfer cap

PP: polypropylene; PS: polystyrene. Dimensions are external selection references, not guaranteed tolerances or working-volume ratings. Confirm the exact supplied configuration before ordering.

Applications

For urine specimen collection and transfer into a matched evacuated tube within a laboratory-approved collection workflow. Component matching and handling must follow the instructions supplied with the exact system.

Ordering Information

Configuration Reference packing
External pickup configuration 50/bag; 400/case
Internal pickup configuration 50/bag; 300/case
PET urine tube, 10 mL 100/tray; 1,200/case

Packing refers to the listed configuration and remains subject to quotation. Sterile and non-sterile formats may use different packaging. Specify your requirements; family images do not define pack contents.

Frequently Asked Questions

Which configurations are covered by this page?

60 mL Urine Collection System. External pickup configuration; Internal pickup configuration. Other capacities are listed separately.

Does nominal capacity mean the required specimen amount?

No. The cup’s 60 mL nominal capacity and the tube’s 10 mL reference capacity describe different components. The cup fill-volume reference is 25–45 mL; the supplied system instructions and laboratory requirements govern actual collection and transfer.

Will any vacuum tube fit the transfer cap?

No universal compatibility is claimed. Confirm the exact tube, closure, pickup geometry and transfer requirements as a matched system. U-bottom and V-bottom describe the closed tube end, not an interchangeable cap specification.

Are these supplied sterile?

Sterility depends on the exact ordering configuration. State your requirement before quotation and confirm the applicable labeling and documentation for the supplied product. A screw cap or individual bag alone does not establish sterility.

What is included in the pack?

Specify cups only, tubes only or a matched system. The group image shows component options and does not mean that every pictured cup and tube is included in one sales pack.

Are the containers approved for every test or transport condition?

No universal test, transport, temperature or market-approval claim is made. Confirm the exact supplied specification against the intended method, destination requirements and laboratory procedure before ordering.

Can I request samples or custom labeling?

Contact Puretest with the required configuration, quantity and destination. Ask about sample availability, label requirements, cap options and packaging before confirming a bulk order.

What information is needed for a quotation?

Provide the 60 mL capacity, pickup design and tube configuration, packing, sterility requirement, quantity and delivery destination. A current product photo or drawing helps confirm the match.

Request a Sample or Quotation

Send the required capacity and configuration, packing, quantity and destination. Contact Puretest for product matching and a quotation.

Gallery images are illustrative product renderings. Final supplied appearance and specification depend on the confirmed configuration.

RELATED PRODUCTS

Illustrative rendering of 100 mL urine collection system in the selected configurations
100 mL Urine Collection System
Illustrative rendering of 90 mL urine collection system in the selected configuration
90 mL Urine Collection System
Illustrative rendering of 60 mL urine collection system in the selected configurations
60 mL Urine Collection System
Tall ten-position Type A Westergren ESR rack with a graduated detection tube
Westergren ESR Rack and Tube System — Type A
GET IN TOUCH

Contact Us

General Inquiries​

Request a Quote or Sample

Tell us the product, specifications and quantity you need. We’ll reply by email with the next steps.