300 µL blue sample pipette tips in a 108-position container for compatible DYNEX DS2, DS2 Elite and DSX systems.
Puretest 300 µL sample pipette tips are designed as an independent compatible consumable for automated sample, standard and control transfers on DYNEX DS2, DS2 Elite and DSX ELISA systems. The blue tip format provides clear visual identification and is supplied in a 108-position sample-tip container for instrument loading.
The 300 µL sample tip is intended for approximately 10–300 µL transfers. It is not the same product as the 1300 µL reagent tip: the two formats use different capacities, instrument positions and workflow roles. The current page has therefore been rebuilt around the correct sample-tip specification rather than copying reagent-tip data.
Important: These are independent compatible consumables, not original DYNEX consumables. Confirm the exact instrument, software method, pipetting role and physical configuration, then qualify the selected item before routine, regulated or diagnostic use.
The ribbed upper collar is designed to create a repeatable mechanical connection with the sample-pipetting adapter. The long, narrow shaft supports access to sample tubes and microplate wells, while the controlled distal orifice helps maintain consistent aspiration and dispense behavior across the 108-position container.
A DYNEX sample-tip container is part of the instrument interface. Tip pitch, container flatness, pickup height and lid or carrier geometry can influence loading and unattended processing. Qualification should include the first and last positions, partially depleted containers, representative sample tubes and the full method volume range.
| Parameter | Specification | Selection note |
|---|---|---|
| Nominal tip capacity | 300 µL | Sample-tip family; do not substitute the 1300 µL reagent tip. |
| Recommended working range | Approximately 10–300 µL | Verify at the method minimum, typical and maximum sample volumes. |
| Instrument role | Sample, standard and control pipetting | Confirm the programmed sample-tip position. |
| Tip color | Translucent blue | Visual distinction from the reagent-tip family. |
| Tip material | Polypropylene | Confirm any purity or sterilization requirement on the quotation. |
| Container format | 108 tips per optimized container with lid | Confirm container, lid, pickup height and lot configuration. |
| Primary platforms | DYNEX DS2, DS2 Elite and DSX | Exact hardware/software configuration requires qualification. |
| Item | Compatibility guidance | What to verify |
|---|---|---|
| DS2 / DS2 Elite | 300 µL sample-tip family; instrument capacity is arranged as two 108-tip sets | Container seating, sample-tip position and method definition. |
| DSX | 300 µL sample-tip family; instrument capacity is arranged as four 108-tip sets | Container seating, pickup path and software method. |
| Pipetting role | Approximately 10–300 µL sample transfer | Samples, standards, controls, mixing and replication steps. |
| 1300 µL reagent tips | Separate tip family | Do not load into the sample-tip position or copy reagent parameters. |
The two DYNEX-compatible tip families perform different functions and must not share copied specifications. The 300 µL format is the sample tip; the 1300 µL format is the reagent tip. Select the tip according to the programmed pipetting role, not only by visual shape or maximum capacity.
| Tip family | Instrument role | Initial working-volume guide |
|---|---|---|
| 300 µL sample tip | Sample, standard and control transfer | 10–300 µL |
| 1300 µL reagent tip | Reagent transfer and dispensing | 20–1000 µL |
For an accurate quotation, provide the exact DYNEX model, 300 µL sample-tip requirement, 108-position container configuration, required sterility/purity status, requested documents, carton quantity and annual demand. Puretest supports evaluation samples, recurring bulk supply, distributor programs and OEM/private-label projects for confirmed configurations.
It is the sample-tip family. The separate 1300 µL format is used for reagent pipetting.
Use approximately 10–300 µL as the initial guide and test the actual minimum, typical and maximum method volumes.
The standard sample-tip layout is 108 positions. Confirm the supplied container and packaging on the quotation.
They are designed for compatible DS2/DS2 Elite and DSX sample-pipetting positions, subject to exact-system qualification.
No. They are independent compatible consumables; validate them on the exact instrument and assay before routine use.
Send the exact instrument model, required tip role, programmed volume range, carrier or tray details, required quality documents and estimated annual demand. We will match the closest configuration for evaluation.
Contact Puretest for a compatibility sample or quotation
DYNEX, DS2 and DSX are trademarks of their respective owner. Puretest is an independent compatible-consumables supplier and is not affiliated with or endorsed by DYNEX Technologies, Inc.
General Inquiries
Please leave your message here! We willsend detailed technical info and quotationto you!