PRODUCTS

Stuart Gel Transport Swab

Stuart Gel specimen transport system with a long narrow tube, fitted swab cap and a short column of clear semisolid transport medium at the tube base.

PRODUCT DETAILS

The Stuart Gel transport swab is a complete microbiology collection-and-transport system consisting of a fitted specimen swab, a long narrow protective tube and a short column of clear semisolid medium at the rounded tube base. Non-nutritive semisolid transport gel designed to maintain bacterial specimen viability during transfer while limiting multiplication before laboratory processing. It is not a vacuum blood collection tube and must be matched to the specimen type, organism target and receiving-laboratory protocol.

Product Highlights

  • Clear / translucent Stuart semisolid transport medium.
  • Complete swab-and-tube system for closed post-collection transfer.
  • Short gel column at the tube base helps keep the inserted swab tip in contact with the specified medium.
  • Tube, swab, sterility, expiration dating and packaging are controlled by the selected SKU.

Structure and Materials

Transport medium Clear / translucent Stuart semisolid transport medium
Tube Long narrow transparent polymer transport tube with rounded base
Closure Fitted ribbed cap with integrated or matched swab applicator
Swab Tip and shaft material selected by the required configuration

Typical Applications

  • Routine bacteriology swab transport when Stuart medium is specified
  • Clinical specimen collection accepted by the receiving microbiology laboratory
  • Short-term transfer to culture under a validated protocol

Use and Handling Overview

  • Open the sterile pack without touching the collection tip.
  • Collect only from the specimen site and by the technique defined in the validated protocol.
  • Insert the swab into the tube so the collection tip reaches the gel column, then secure the closure.
  • Label, store and transport the system within the time and temperature limits specified for the selected SKU and receiving method.

Important: The customer is responsible for validating the complete collection, transport and downstream test workflow.

Technical Specifications

Transport medium Clear / translucent Stuart semisolid transport medium
Tube Long narrow transparent polymer transport tube with rounded base
Closure Fitted ribbed cap with integrated or matched swab applicator
Swab Tip and shaft material selected by the required configuration
Medium appearance Clear, translucent or pale; formulation dependent
Primary medium role Non-nutritive semisolid transport gel designed to maintain bacterial specimen viability during transfer while limiting multiplication before laboratory processing.
System type Microbiology swab transport device; not a blood collection tube
Sterility Configuration dependent; confirm the exact SKU
Packaging Configuration dependent; confirm inner and outer pack quantities
Shelf life / storage Confirmed from the selected SKU documentation

Selection Guide

Choose Stuart only when the laboratory method names Stuart medium; it is not automatically interchangeable with Amies or Cary-Blair. Medium, swab material, specimen source and downstream method are not automatically interchangeable. Confirm the exact validated configuration before ordering.

Ordering Information

Product family Stuart Gel Transport Swab
Configuration Tip, shaft, tube, sterility and packaging confirmed before quotation
OEM service Label and packaging discussion available after technical review
Request details Application, specimen type, required geometry or medium, pack quantity and expected order volume

Frequently Asked Questions

Is this a blood collection tube?

No. It is a long narrow microbiology transport tube supplied around a specimen swab and a short gel column.

Is the transport medium interchangeable with other media?

No. Use Stuart only when it is accepted by the validated collection and receiving-laboratory protocol.

What does the charcoal version change?

This clear version does not contain charcoal. If the method requires adsorption of inhibitory compounds, ask whether the matching charcoal formulation is specified.

Is the tube filled with liquid?

No. The illustration shows a short column of semisolid transport medium at the tube base.

Where should the swab tip sit after collection?

When the validated instructions require it, the inserted collection tip should reach the semisolid medium column before the closure is secured.

Which swab tip is included?

Tip and shaft material depend on the selected configuration and are confirmed before quotation.

Is the system sterile?

Sterile configurations may be available; the method, shelf life and documentation are SKU specific.

Can cap color be used as the only identifier?

No. Cap color may vary by configuration. Always verify the printed SKU and medium specification.

What should I send for a quotation?

Provide required medium, charcoal or clear version, specimen type, swab preference, sterility, pack quantity and order volume.

Request a Matched Configuration

Send Puretest your application, required configuration and order volume. Our team will confirm the matching SKU, documentation and packaging before quotation.

RELATED PRODUCTS

White breathable heat sealing film roll with a brown core and an unrolled membrane section
Breathable Heat Sealing Film
Transparent heat sealing film roll with a white core and clear unrolled film
Clear Heat Sealing Film
Roll of aluminum heat sealing foil with an unrolled silver foil section
Aluminum Heat Sealing Foil
Single pipette tip accessing a microplate well through a cross-shaped pre-slit sealing film opening
Pierceable and Pre-Slit Microplate Sealing Film
GET IN TOUCH

Contact Us

General Inquiries​

Leave info for details

Please leave your message here! We willsend detailed technical info and quotationto you!