Puretest P30 / P30XL robotic pipette tips are intended for low-volume automated transfers where standard and extended-reach geometries must be selected deliberately. This page is structured for automation engineers, laboratory managers, procurement teams, distributors and OEM buyers who need an auditable selection process rather than a generic statement that a tip “fits.”

Beckman platform literature distinguishes P30 and P30XL tip families for selected Biomek i-Series workflows. P30 is referenced to approximately 30 µL maximum capacity or 25 µL when filtered, while P30XL is referenced to approximately 50 µL or 40 µL when filtered. These families are not listed for older Biomek 2000/3000/4000 contexts, and the published platform references do not describe them as conductive or wide-bore options.

Reliable automated pipetting depends on the complete system: instrument, installed head or channel, tip-cone interface, rack, carrier, software tip definition, liquid class, source and destination labware and liquid properties. Puretest recommends sample qualification with the intended method before routine or validated use.

Product Highlights

  • Application-focused family: P30 / P30XL selection for low-volume automated transfers where standard and extended-reach geometries must be selected deliberately.
  • Automation format: Biomek-compatible automation rack for compatible Beckman Biomek workflows.
  • Transparent option control: filter, sterility, conductivity, special geometry and packaging are confirmed by exact SKU.
  • Full-head qualification: structured checks for rack seating, pickup, seal, liquid class, channel consistency and ejection.
  • Document support: current material, cleanliness, sterility and lot records can be requested for qualified configurations.
  • Commercial support: evaluation samples, international supply, distributor and OEM/private-label programs are available.

Tip Structure and Functional Design

A robotic pipette tip functions as part of a mechanical and fluidic system. Cone-interface consistency influences sealing and pressure behavior; shaft geometry affects labware access; the distal section influences residual liquid and dispense behavior; and rack registration determines multi-channel pickup reliability. Filter placement, orifice geometry and material can each change usable volume or liquid-class performance.

Qualification must therefore use the exact sellable configuration. A change from non-filtered to filtered, standard to extended or wide-bore, clear to conductive, or non-sterile to sterile supply should be documented and the relevant mechanical and liquid-handling checks repeated.

Technical Specifications and Selection Notes

Specification Family / Platform Context Qualification or Ordering Note
P30 platform reference Up to approx. 30 µL non-filtered / 25 µL filtered Confirm selected i-Series head and Puretest SKU
P30XL platform reference Up to approx. 50 µL non-filtered / 40 µL filtered Extended geometry may change labware access and liquid class
Platform context Selected Biomek i-Series workflows Not positioned from platform literature for Biomek 2000/3000/4000
Geometry P30 standard reach; P30XL extended reach Confirm source/destination depth and collision clearance
Conductivity Not assumed for this family Do not claim conductive sensing without exact SKU confirmation
Filter / sterile Configuration-dependent Filtered capacity is lower; request current sterility documents
Rack Biomek-compatible automation rack Verify pickup, rack seating, lid clearance and ejection

Platform-literature values describe the compatible automation context; they do not create a universal Puretest performance guarantee. Puretest will confirm the actual quoted configuration, available documents and sample plan.

Platform, Head and Rack Compatibility

Beckman platform literature distinguishes P30 and P30XL tip families for selected Biomek i-Series workflows. P30 is referenced to approximately 30 µL maximum capacity or 25 µL when filtered, while P30XL is referenced to approximately 50 µL or 40 µL when filtered. These families are not listed for older Biomek 2000/3000/4000 contexts, and the published platform references do not describe them as conductive or wide-bore options.

Qualification Item Why It Matters Recommended Check
Instrument and head One platform family may support multiple heads and tip definitions Provide the exact platform, installed head/pod and software method
Rack and carrier Footprint, height and registration determine reliable pickup Confirm carrier, deck coordinates, lid clearance and rack seating
Pickup, seal and ejection Mechanical consistency affects pressure, retention and error rate Inspect every active channel across representative deck positions
Liquid class Viscosity, volatility, surface tension and foaming change transfer behavior Tune speeds, delays, immersion depth, pre-wetting, air gaps and tip touch
Critical transfer points A nominal family does not guarantee every method volume Test minimum, routine and maximum critical volumes with real liquids
Variant changes Filters, material, geometry and sterility can alter behavior Requalify each materially different sellable configuration

For second-source qualification, send the exact platform, installed head or pod, current tip reference or drawing when available, rack carrier, target volumes, liquids, filter and sterility needs and annual consumption.

Available Material, Filter and Packaging Configurations

Configuration Typical Reason to Select What to Confirm
P30 standard Routine low-volume transfers Maximum critical volume and labware access
P30XL extended Deeper vessel access or workflow-specific reach Collision clearance and liquid-class requalification
Non-filtered Maximum internal-volume flexibility Sterility and cleanliness requirements
Filtered / sterile Aerosol-barrier or contamination-controlled work Effective capacity, wrapping and lot documents

Not every option is necessarily available in every volume and rack combination. The final quotation should identify material, conductivity, filter state, sterility, rack format, wrapping, case quantity and required technical documents.

Typical Applications

  • PCR workflow setup
  • low-volume normalization
  • assay plate preparation
  • reagent addition
  • deep or recessed labware access with P30XL

P30 and P30XL should not share a liquid class automatically. Shaft length, internal geometry, filter state and access depth can alter aspiration and dispense behavior. Qualify the exact geometry at every critical deck position.

Method Development and Qualification Workflow

  1. Verify mechanical fit: inspect rack seating, pickup, vertical alignment, seal, retention and ejection across all active channels.
  2. Verify deck integration: confirm carrier, rack height, lid clearance, pickup coordinates and access from required positions.
  3. Configure sensing: confirm whether conductive liquid-level detection or another detection strategy is required.
  4. Optimize the liquid class: evaluate aspiration and dispense speeds, delays, immersion depth, pre-wetting, air gaps, mixing and tip touch.
  5. Challenge real liquids: include aqueous, viscous, volatile, foaming, particulate or low-surface-tension liquids used by the process.
  6. Measure performance: verify accuracy, precision, residual volume, channel consistency, carryover risk and error recovery.
  7. Record the approved setup: document tip SKU, lot, rack, instrument/head and liquid-class version for change control.

Quality, Sterility and Technical Documentation

Automation consumables may require material information, product specifications, irradiation or sterility records, lot traceability, certificate of analysis and RNase/DNase or pyrogen/endotoxin declarations. Availability and limits depend on the exact SKU and current production configuration.

Do not transfer a claim from another capacity, material or package format. State required documents in the RFQ so Puretest can confirm what applies before order placement. Customers remain responsible for final qualification in regulated or validated workflows.

Packaging, Logistics and Supply Continuity

Racked robotic tips can be supplied in configurations appropriate to the selected platform and market. Confirm rack footprint, lid, wrapping, sterile state, label, barcode or lot-data needs, case quantity and pallet/carton requirements. Supply planning may include evaluation lots, production batches, annual forecasts and safety stock.

For international orders, provide delivery country, annual or monthly demand and required import or technical documents. Configuration, minimum order quantity and lead time are confirmed during quotation.

Selecting the Correct Tip within the Beckman Biomek Family

Biomek-compatible selection may include P20, P30, P30XL, P50, P250 and P1000 families. P30/P30XL selection is driven by usable volume and access geometry; a higher family is not automatically safer for the lowest transfer points.

Choose the smallest capacity that comfortably covers the validated transfer range, while matching the installed head and rack format. A protocol spanning substantially different volumes may benefit from more than one tip family.

RFQ Information Checklist

Information to Send Example Why It Helps
Platform and installed head Beckman Biomek Prevents selection by brand name alone
Target transfer range P30 / P30XL Supports capacity and filter-state selection
Rack / carrier Biomek-compatible automation rack Confirms footprint, density and pickup geometry
Liquid characteristics Aqueous, viscous, volatile, foaming, cells or beads Guides geometry and qualification planning
Required options Filter, sterile, conductive, nested or special geometry Defines the exact quotation variant
Commercial details Annual quantity, delivery country and required documents Supports MOQ, lead time and logistics review

A complete RFQ enables Puretest to recommend a specific sellable configuration and reduces sample cycles, especially when multiple rack or filter variants exist under the same nominal capacity.

International, Distributor and OEM Support

Puretest supports laboratories, automation integrators, distributors and private-label buyers serving Europe, North America and other international markets. Programs can cover evaluation samples, annual demand, safety stock, carton configuration, labels, artwork, lot information and shipping documents.

OEM/private-label availability is subject to configuration, minimum order quantity, forecast, artwork and lead-time review. Private labeling does not remove the need for customer-side compatibility and method qualification.

Frequently Asked Questions

Are these original Beckman Biomek tips?

No. They are Puretest-manufactured robotic pipette tips designed for compatibility with specified Beckman Biomek workflows. Puretest is not affiliated with or endorsed by the instrument manufacturer.

Does the P30 / P30XL family name guarantee every transfer point?

No. Usable performance depends on platform, head or channel, filter, internal geometry, liquid class and application. Use the family as a selection starting point and validate critical transfers.

How do I confirm platform compatibility?

Provide the exact instrument, installed head or pod, rack/carrier and current tip reference when available. Test a sample for pickup, sealing, ejection and liquid-handling performance.

Are filtered and sterile versions available?

Availability is configuration-dependent. State filter, sterility, wrapping and required documents in the RFQ so the exact sellable configuration can be confirmed.

Can a filtered tip use the same liquid class as a non-filtered tip?

Do not assume so. A filter changes usable internal space and can affect fluid behavior. Qualify the filtered configuration separately.

Are conductive tips required?

Only when the validated method uses a compatible conductive liquid-level-detection strategy or another requirement specifies conductive material. Confirm hardware and method settings.

Can we receive samples before a production order?

Yes. Sample evaluation is recommended before routine use, particularly for a new method or second-source qualification.

What information speeds up a quotation?

Send platform, installed head or pod, target volumes, liquids, filter, sterility, conductivity, rack, documents, annual quantity and delivery country.

Request a Compatibility Sample, Technical Document or Quotation

Send your Beckman Biomek platform and head configuration, P30 / P30XL requirement, rack format, filter, sterility, conductivity or special-geometry needs, required documents, expected annual quantity and delivery country. Puretest will confirm the closest sellable configuration and sample plan.

Contact Puretest for a sample, technical document or quotation

Trademark notice: Beckman Coulter and Biomek are trademarks or registered trademarks of their respective owner. Puretest is not affiliated with or endorsed by the instrument manufacturer. Compatibility references identify intended instrument use only.

RELATED PRODUCTS

high-density robotic pipette tip rack compatible with Tecan Fluent MCA 384 automation
Robotic Pipette Tips Compatible with Tecan MCA 384, 15–500 µL
1000 µL robotic pipette tip rack compatible with Tecan Fluent MCA 96 automation
1000 µL Robotic Pipette Tips Compatible with Tecan MCA 96
P1000 clear large-volume robotic pipette tip compatible with Beckman Biomek automation
P1000 Robotic Pipette Tips Compatible with Beckman Biomek
P30 and longer P30XL robotic pipette tips compatible with Beckman Biomek automation
P30 & P30XL Robotic Pipette Tips Compatible with Beckman Biomek
GET IN TOUCH

Contact Us

General Inquiries​

Leave info for details

Please leave your message here! We willsend detailed technical info and quotationto you!