PRODUCTS

200 µL Filtered Pipette Tips Compatible with Opentrons OT-2

200 µL filtered OT-2-compatible tips for medium-volume automated liquid handling on P300 GEN2 pipettes.

  • 5–200 µL working-volume target
  • Clear polypropylene with aerosol barrier
  • 96-position rack
  • For OT-2 P300 GEN2 1-channel and 8-channel pipettes

Request a compatibility sample or quotation

PRODUCT DETAILS

200 µL Filtered Pipette Tips Compatible with Opentrons OT-2

Puretest 200 µL filtered tips are designed as an independent compatible option for Opentrons OT-2 P300 GEN2 liquid-handling workflows. They combine a clear polypropylene fluid path with an aerosol barrier for medium-volume transfers where contamination control is important.

The 200 µL filtered format is distinct from the 300 µL non-filtered format even though both are commonly associated with P300-class pipettes. Capacity, shaft geometry, filter position and liquid-class settings should therefore be selected and validated as a complete method rather than inferred from pipette name alone.

Important: Compatibility and performance must be established on the exact OT-2, P300 pipette, rack definition and protocol. Do not substitute a 200 µL filtered tip for a 300 µL non-filtered tip without method qualification.

Product Highlights

  • 200 µL filtered format: recommended starting range approximately 5–200 µL.
  • Aerosol barrier: supports contamination-conscious molecular and cell-based workflows.
  • P300 compatibility target: for OT-2 P300 GEN2 1-channel and 8-channel pipettes.
  • 96-position rack: automation-ready footprint after rack-definition and pickup qualification.
  • Clear polypropylene: non-conductive material enables visual fluid inspection.
  • Evaluation support: samples and available documents for laboratories and distributors.

Tip Structure and Functional Design

The filtered 200 µL tip uses a tapered clear polypropylene shaft and an internal hydrophobic barrier. Uniform cone dimensions support sealing on the pipette nozzle, while controlled wall thickness and orifice geometry help maintain predictable aspiration, dispense and blow-out behavior across the rack.

Medium-volume protocols frequently involve different liquid viscosities, mixing cycles and immersion depths. Qualification should therefore include both water-like and representative process liquids, the smallest and largest routine volumes, and the exact labware used in production.

Technical Specifications and Selection Notes

Parameter Specification Selection note
Nominal tip capacity 200 µL Filtered format for P300-class workflows.
Recommended working range Approximately 5–200 µL Verify performance at method-specific limits.
Tip material Clear, non-conductive polypropylene No capacitive sensing function.
Barrier Hydrophobic aerosol filter Avoid contact between liquid and filter.
Rack format 96 positions, ANSI/SLAS footprint Confirm deck placement and labware definition.
Primary pipettes OT-2 P300 GEN2, 1-channel and 8-channel Confirm multichannel pickup across all eight nozzles.
Autoclaving Not recommended Use documented supplied condition.

Platform, Pipette and Rack Compatibility

Item Compatibility guidance What to verify
Robot Opentrons OT-2 Hardware generation and software/protocol context.
Pipettes P300 GEN2 single-channel and 8-channel Cone sealing, pickup, tip length and ejection.
Tip definition 200 µL filtered OT-2-compatible rack Correct rack geometry and Z offsets.
Related option 300 µL non-filtered OT-2-compatible tip Use the separate page and validate different capacity/configuration.
Cross-platform use Not for Flex pipettes OT-2 and Flex tips are not interchangeable.

Filtered, Non-Filtered and Packaging Configurations

This page covers the 200 µL filtered rack. The corresponding non-filtered OT-2 P300-family configuration is normally 300 µL and is listed separately. Confirm the required barrier, capacity and sterility/purity documentation before ordering.

Configuration Best suited to Supply / qualification note
200 µL filtered rack Contamination-sensitive medium-volume transfer 96-tip complete rack.
300 µL non-filtered rack/refill Routine transfer requiring the larger 300 µL envelope Separate product configuration and qualification.

Quality and Configuration Control

  • Controlled molding and dimensional inspection support repeatable nozzle sealing, pickup height and ejection behavior across the 96-position rack.
  • Transparent polypropylene provides direct visual confirmation of liquid movement and residual droplets; filtered versions include a hydrophobic barrier selected for the intended format.
  • Specified sterile or purity-controlled supply is available only when confirmed for the selected item and supported by current lot documents.
  • Lot identification, packaging integrity, dimensional drawings, material declarations and available quality documents can be supplied for the confirmed ordering configuration.
  • Sterility, purity, filter, packaging and shelf-life claims apply only when they are listed on the current quotation, specification sheet and lot documentation.

Typical Applications

  • PCR/qPCR and NGS preparation
  • Reagent distribution and plate setup
  • Sample normalization and dilution
  • Cell-based assay liquid handling
  • Automated mixing and serial dilution after validation

Recommended Qualification Workflow

  1. Confirm the platform: identify the exact robot, pipette model, channel count and installed software or protocol definition.
  2. Select the smallest suitable capacity: choose a tip whose qualified working range covers the intended transfer volume.
  3. Confirm the configuration: filtered or non-filtered, rack or refill, sterile or non-sterile, and required purity documentation.
  4. Run mechanical checks: evaluate full-rack pickup, nozzle sealing, tip height, labware clearance and clean ejection.
  5. Run liquid-handling checks: confirm aspiration, dispense, residual volume, accuracy, precision and contamination control with representative liquids and labware.
  6. Lock the approved item: record the final item code, tip configuration, rack definition and validated protocol settings before routine procurement.

Ordering Information

To receive the correct quotation, specify: OT-2 model, P300 pipette and channel count, 200 µL filtered requirement, rack quantity, sterile/purity requirements and required qualification documents. Puretest supports evaluation samples, distributor supply, recurring bulk orders and OEM/private-label programs for confirmed configurations.

Frequently Asked Questions

Why is the filtered tip 200 µL instead of 300 µL?

The filter occupies part of the internal volume and the filtered configuration is specified as a separate 200 µL format.

Can it be used on P300 pipettes?

It is designed for compatible P300 GEN2 single- and 8-channel workflows, subject to mechanical and liquid-handling qualification.

What happens if liquid reaches the filter?

A wetted filter can reduce recovery and change transfer behavior; review aspiration volume, immersion depth and liquid class.

Is this tip compatible with Flex?

No. OT-2 and Flex tips have different interfaces.

Can I request an evaluation rack?

Yes. Provide the robot, pipette, method volumes and representative liquids for the most useful evaluation.

Request Samples, Documents or a Quotation

Send your robot model, pipette model, channel count, target volume, filtered/non-filtered preference, rack/refill preference, sterility requirement and estimated annual demand. We will match the most appropriate configuration and provide available qualification documents.

Contact Puretest for an evaluation sample or quotation

Opentrons and the related product names are trademarks of their respective owner. Puretest is an independent compatible-consumables supplier and is not affiliated with or endorsed by Opentrons Labworks, Inc.

RELATED PRODUCTS

2.3 mL 96-well diamond-bottom deep well plate
2.3 mL 96-Well Diamond-Bottom Deep Well Plate
high-density robotic pipette tip rack compatible with Tecan Fluent MCA 384 automation
Robotic Pipette Tips Compatible with Tecan MCA 384, 15–500 µL
1000 µL robotic pipette tip rack compatible with Tecan Fluent MCA 96 automation
1000 µL Robotic Pipette Tips Compatible with Tecan MCA 96
P1000 clear large-volume robotic pipette tip compatible with Beckman Biomek automation
P1000 Robotic Pipette Tips Compatible with Beckman Biomek
GET IN TOUCH

Contact Us

General Inquiries​

Leave info for details

Please leave your message here! We willsend detailed technical info and quotationto you!